Facebook Pixel

Amana-Goodman 0151M00037S Natural Gas Valve Furnace 24V

Special Price $69.44 Regular Price $80.95
In stock
SKU
0151M00037S
The Amana-Goodman 0151M00037S is a key component in natural gas furnaces, specifically regulating the flow of gas to the burner. Made of aluminum for strength and weighing in at 1.73 lbs, this 24V valve is a compact size at 3.7 inches. It operates within a wide temperature range of -40°F to 175°F, ensuring durability in various climates. This valve plays a critical role in safe and efficient furnace operation. It utilizes a pressure regulator to maintain a constant ½ psi gas pressure, even with fluctuating incoming pressure. This consistent gas pressure ensures optimal burner performance and efficient heating throughout your home. The 105,000 BTU maximum regulator capacity means it can handle the gas flow requirements of most residential furnaces. With a secure National Pipe Thread (NPT) connection and a frequency of 60 Hz for smooth operation, the Amana-Goodman 0151M00037S valve is a reliable replacement part for your natural gas furnace.
Manufacturer:
https://www.partshnc.com/media/catalog/product/0/1/0151m00037s.jpg

Specifications

  • Size: 3.7 Inch
  • Meterial: Aluminium
  • Pressure Regulator(psi): 1/2 Psi
  • Temperature Range (F)/(c): -40°F-175°F
  • Weight: 1.73 lbs
  • Maximum Regulator Capacity: 105,000BTU
  • Connection type: NPT
  • Frequency: 60 Hz
  • Type of Gas: Natural Gas
  • Voltage: 24V
Manufacturer Name: Amana-Goodman
Product Number: 0151M00037S
OEM Part Number: 0151M00037S
Product Description: 24V Natural Gas Valve
Weight:1.73lbs/784.71g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Amana-Goodman 0151M00037S Natural Gas Valve Furnace 24V
Your Rating
Customer Questions
What maintenance is required for the Amana-Goodman 0151M00037S Natural Gas Valve?

Inspect the valve and wiring regularly for corrosion or loose connections. Ensure gas lines remain leak-free and clean to maintain proper flow. Regular checks can prevent furnace malfunction and improve safety during operation.

What are common issues with the Amana-Goodman 0151M00037S Natural Gas Valve?

  • Gas valve sticking or failing to open.
  • Intermittent ignition or burner shutdown.
  • Weak or inconsistent gas flow leading to heating issues.
  • Noisy operation or clicking during startup.
  • Complete furnace shutdown due to valve malfunction.

Installation Steps

Step 1: Disconnect electrical power and shut off gas supply, check isolation.

Step 2: Remove old gas valve, label wiring and gas line connections.

Step 3: Place new valve onto manifold and secure mounting screws.

Step 4: Reconnect control wires and gas piping using correct fittings.

Step 5: Tighten all connections and ensure proper sealing.

Step 6: Restore power and gas, check ignition sequence.