York S1-031-09162-000 2-Stage Heat Control Board

Special Price $229.65 Regular Price $254.91
In stock
SKU
S1-031-09162-000
The York S1-031-09162-000 is an essentialunit designed for application in HVAC systems used for heating control. This system manages to provide comfort and practicality by controlling the system’s output in a 2-stage heat control board. This board provides constant indoor temperature and also controls the heating stages to avoid wastage of energy. This is attained by fluctuating between low and high stages where by the heater switches its operation to match the heating call. These are the lessons as follows: It achieves considerable energy saving and improves system performance.
Manufacturer:
https://www.partshnc.com/media/catalog/product/0/0/0019582_0.jpg

Specifications

  • Type: Heat Control Board
  • Number of Stages: 2
Manufacturer Name: York
Product Number: S1-031-09162-000
OEM Part Number: S1-031-09162-000
Product Description: 2Stage Heat Control Board
Weight:0.69lbs/312.98g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:York S1-031-09162-000 2-Stage Heat Control Board
Your Rating
Customer Questions
How to install an expansion valve for refrigeration?

Thermostatic expansion valves are an integral part of your refrigeration unit. They are responsible for ensuring the right dosage of refrigerant is entering the cooling coil to ensure maximum efficiency in the air conditioning of the system.    These special expansion valves come with a temperature sensor that is mounted at the end of the evaporator coil. They incorporate signals from this sensor to maintain the required temperature of the HVAC system. The thermostatic expansion valve works like a precision device that can regulate the measurements of the liquid refrigerant that flows into the evaporator of your system. This regulation in the flow of the refrigerant is essential to prevent the reverse flow of the refrigerant into the compressor of your system.    Through this mechanism, the thermostatic expansion valve successfully separates the high and low pressure sides of the refrigeration/air conditioning system. The liquid refrigerant enters the expansion ...

Please, mind that only logged in users can submit questions