Johnson Controls V47AB-5 Temperature Actuated Valve 1/2" 75°F-135°F
Specifications
- Weight: 4.3 lbs
- Type: Valve
- Material: Cast Brass
- Size: 1/2"
- Temperature range: 75°F to 135°F
Loyalty ProgramPRODUCT OVERVIEW:
Temperature actuated water regulating valves manage cooling liquid flow using remote thermal sensing. The Johnson Controls V47AB-5 Temperature Actuated Valve 1/2" 75°F-135°F is an OEM component designed to provide automatic flow control in compatible water-regulated systems. This direct-acting valve opens its internal fluid passage as temperatures rise at the sensing bulb. By modulating cooling water volume to dissipate heat under changing load conditions, the unit preserves equipment operating efficiency and prevents system overheating.
REMOTE THERMAL SENSING:
Thermal fluid expansion inside the remote sensing bulb drives internal valve positioning through an armored capillary tube. As temperature increases at the bulb, fluid pressure travels down the capillary to push the valve seat open against spring tension. The direct-acting mechanism opens further under higher heat loads to allow maximum cooling water flow. When temperatures drop back toward setpoint, internal spring force balances the hydraulic pressure to throttle water throughput.
CROSS AMBIENT FLOW REGULATION:
Featuring a cross-ambient element design, this valve maintains accurate temperature response regardless of surrounding air conditions along the capillary line. Operating across a 1/2" NPT cast brass body, the valve regulates water passage strictly based on thermal conditions at the sensing location. This isolated sensing capability ensures consistent flow modulation across the entire 75°F to 135°F adjustment range.
REPLACEMENT GUIDELINES:
Component replacement is necessary when the valve fails to open on temperature rise, displays internal seat binding, or suffers capillary charge loss. Malfunctioning water regulating valves disrupt equipment cooling by causing high-head-pressure lockouts, insufficient heat dissipation, or water waste. Qualified technician assistance is recommended for hydronic line piping, pressure testing, and thermal bulb installation. Before purchasing, verify the part number and all relevant specifications against the original equipment documentation to ensure the replacement matches the system requirements.
COMMON FAILURE SYMPTOMS:
EQUIPMENT COMPATIBILITY:
The Johnson Controls V47AB-5 is intended for compatible water and refrigeration systems requiring a 1/2" NPT direct-acting temperature actuated valve with a Style 4 bulb and cross-ambient element. Confirm the part number and relevant specifications against the original equipment documentation before selecting a replacement. For exact compatible equipment models, refer to the manufacturer's documentation. Do not assume compatibility based on the manufacturer name alone.
TECHNICAL SPECIFICATIONS:
Product Identification:
Brand: Johnson Controls
Part Number: V47AB-5
Component Type: Temperature Actuated Water Regulating Valve
Material Details:
Body Material: Cast Brass
Operating Conditions:
Valve Action: Direct Acting (Opens on Temp Rise)
Temperature Range: 75°F to 135°F (Cross Ambient)
Connection Specifications:
Main Connection: 1/2" NPT
Sensing Specifications:
Capillary Length: 6 Feet
Bulb Dimensions: 11/16" Diameter x 10" Length (Style 4)
Bulb Fitting: 1/2" NPT External Fitting
Step1: Turn off system power and close the water or fluid supply.
Step2: Remove the existing valve from the pipeline.
Step3: Clean the pipe ends to ensure a proper seal.
Step4: Install the new actuated valve in the same orientation, tightening connections securely.
Step5: Adjust the temperature setpoint if required according to instructions.
Step6: Restore power and fluid flow, then test the valve for proper operation.