Johnson Controls V46AE-1 Pressure Actuated Water Regulator Valve 1 1/4" 70-260 PSI

Special Price $652.81 Regular Price $724.62
Out of stock
SKU
V46AE-1
The Johnson Controls V46AE-1 valve is an automatic valve used to control pressure and flow of water in HVAC systems. It has a cast iron valve body and has a flow size of 1-1/4 ” NPT which goes well in most applications with high pressure.This 2-way valve works under the pressure range of which it ensures high stability and optimum water control. This valve works based on change in pressure within a system with the valve responding to change in pressure. As pressure increases the valve opens to let more water through so that pressure reduces. As pressure decrease, the valve shuts, thereby decreasing the rate of water flow whilst increasing pressure.
https://www.partshnc.com/media/catalog/product/v/4/v46ae-1.jpg

Specifications

  • Weight: 8.76 lbs
  • Type: Pressure-Actuated Water Regulating Valve
  • Valve Body Material: Cast Iron
  • Connection Size: 1-1/4" NPT
  • Pressure: 70-260 PSI
  • Valve Style: 2-Way
Manufacturer Name: Johnson Controls
Product Number: V46AE-1
OEM Part Number: V46AE-1
Product Description: 1 1/4"70/260#,#Act.H20 Reg.Vlv
Weight:8.76lbs/3973.47g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Johnson Controls V46AE-1 Pressure Actuated Water Regulator Valve 1 1/4" 70-260 PSI
Your Rating
Customer Questions
What maintenance is required for the Johnson Controls V46AE-1 Pressure Actuated Water Regulator Valve?

Inspect the valve regularly for leaks, corrosion, and scaling. Clean internal components and strainers periodically to maintain accurate pressure control. Ensure inlet pressure remains within rated limits and replace worn seals to prevent malfunction and water damage.

What are common issues with the Johnson Controls V46AE-1 Pressure Actuated Water Regulator Valve?

  • Pressure fluctuation or unstable outlet flow.
  • Internal diaphragm wear or rupture.
  • Valve sticking due to sediment buildup.
  • Leakage at connections or seals.
  • Reduced flow from clogging or corrosion.

Installation Steps

Step 1: Turn off main water supply and depressurize system for safety.

Step 2: Choose installation point on main line, ensure accessibility.

Step 3: Verify flow direction arrow matches pipeline direction.

Step 4: Apply thread sealant to fittings for leak prevention.

Step 5: Install valve and tighten connections securely.

Step 6: Secure alignment and supports to avoid vibration.

Step 7: Restore water slowly, check for leaks.