The Carrier EA36UZ067 Thermal Expansion Valve (TXV) is an essential part of Carrier HVAC systems that use R-410A refrigerant. It is a small box-like device with dimensions of 5 x 3.25 x 3.5 inches, and this is essentially essentialin controlling the refrigerant flow in the system. The TXV has a bi-metallic component that changes its dimensions with changes in temperature. This expansion and contraction control the refrigerant flow to the evaporator coil to make sure it cools properly for the greatest efficiency of the entire working process.
Manufacturer:
https://www.partshnc.com/media/catalog/product/e/a/ea36uz067.jpg

Specifications

  • Length: 5 "
  • Width: 3.25 "
  • Height: 3.5 "
  • Composition: Bi-Metal
  • Metering Device: TXV/TEV - Thermostatic Expansion Valve
  • Refrigerant: R-410A
  • Weight: 1.13lbs
Manufacturer Name: Carrier
Product Number: EA36UZ067
OEM Part Number: EA36UZ067
Product Description: Thermal Expansion Valve
Weight:1.13lbs/512.56g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Carrier EA36UZ067 Thermal Expansion Valve
Your Rating
Customer Questions
What maintenance is required for the Carrier EA36UZ067 Thermal Expansion Valve?

Inspect the valve bulb and sensing line for secure mounting and leaks, and ensure proper refrigerant charge. Clean surrounding components and check superheat settings periodically. Regular inspection helps maintain efficient cooling and prevents system imbalance or compressor pressure.

What are common issues with the Carrier EA36UZ067 Thermal Expansion Valve?

  • Refrigerant under/overcharge affecting superheat.
  • Stuck or miscalibrated expansion valve.
  • Sensing bulb loss of contact or insulation issues.
  • Restriction/blockage from debris or moisture freezing.
  • Erratic superheat control due to valve hunting.

Installation Steps

Step 1: Turn off system power and recover appliance safely.

Step 2: Remove old valve from evaporator inlet/outlet lines carefully.

Step 3: Clean and inspect copper lines for debris or damage.

Step 4: Position new TXV in correct flow direction and orientation.

Step 5: Braze connections using nitrogen purge while avoiding overheating.

Step 6: Attach sensing bulb tightly on suction line and insulate properly.

Step 7: Vacuum system, leak-test, then recharge refrigerant to specification.