Facebook Pixel

Copeland 998-0066-00 Solenoid Valve & Tubing Kit

Special Price $196.27 Regular Price $225.71
In stock
SKU
998-0066-00
The Copeland 998-0066-00 Solenoid Valve Tube Kit is a fastener of precision and dependability which regulates in HVAC systems. This kit consists of a solenoid valve, along with all tubes needed for controlling refrigerant flow through your entire unit. Such valves are considered as electromechanical devices that open and close based on electrical inputs provided by the HVAC controller. Thus, this valve regulates the flow of refrigerant so that it may either be allowed to pass or be blocked off when necessary, thus ensuring the better functioning of the entire unit. Kits such as these are used by HVAC experts to achieve high levels of accuracy in regard to refrigerant controls thereby increasing its efficiency and dependability.
Manufacturer:
https://www.partshnc.com/media/catalog/product/9/9/998-0066-00_1.jpg

Specifications

  • Type:Valve & Tubing Kit
  • Weight: 0.43lbs
Manufacturer Name: Copeland
Product Number: 998-0066-00
OEM Part Number: 998-0066-00
Product Description: Solenoid Valve & Tubing Kit
Weight:0.43lbs/195.04g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Copeland 998-0066-00 Solenoid Valve & Tubing Kit
Your Rating
Customer Questions
What maintenance is required for the Copeland 998-0066-00 Solenoid Valve And Tubing Kit?

Inspect the solenoid valve and tubing assembly regularly for refrigerant leaks, loose fittings, corrosion, or damaged tubing. Verify that the valve energizes and closes properly during system operation and ensure tubing remains free of kinks or restrictions. Routine inspection helps maintain proper refrigerant flow and accurate compressor performance.

What are common issues with the Copeland 998-0066-00 Solenoid Valve And Tubing Kit?

  • Solenoid valve failing to open or close properly.
  • Refrigerant leakage at tubing connections or fittings.
  • Restricted refrigerant flow caused by blocked or damaged tubing.
  • Coil failure preventing valve actuation.
  • Intermittent valve operation due to electrical faults.

Installation Steps

Step 1: Turn off power and refrigerant flow before starting.

Step 2: Identify correct installation point in the system line.

Step 3: Mount the solenoid valve securely in the proper flow direction.

Step 4: Connect tubing firmly, ensuring leak-proof fittings.

Step 5: Wire the solenoid coil per the wiring diagram.

Step 6: Restore power and check for leaks or loose connections.