The York S1-025-31834-000 Manual Reset Limit Switch is a safety object used to prevent the overheating of HVAC equipment. This limit switch is specifically designed to open the circuit at the temperature of 160°F. When the temperature inside the HVAC system reaches this level, the limit switch opens to cut off power to the equipment. This makes sure that further destruction occurs not to mention fires that could occur due to other causes. The manual reset feature makes the operator reset the switch after the overheating condition has been cleared to avoid the system being switched on while still in the danger zone. This kind of limit switch is widely applied in chillers, boilers, air handlers, etc.
Manufacturer:
https://www.partshnc.com/media/catalog/product/s/1/s1-025-31834-000_1.jpg

Specifications

  • Type: Limit Switch
  • Switch Type: Manual Reset
  • Open Temperature: 160°F
Manufacturer Name: York
Product Number: S1-025-31834-000
OEM Part Number: S1-025-31834-000
Product Description: M/R Limit Switch; 160Op
Weight:0.06lbs/27.22g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:York S1-025-31834-000 Manual Reset Limit Switch 160°F Open
Your Rating
Customer Questions
What maintenance is required for the York S1-025-31834-000 Limit Switch?

Inspect the limit switch periodically for secure mounting, proper wiring connections, and signs of overheating or physical damage. Ensure airflow restrictions, clogged filters, and blocked vents are corrected to prevent nuisance tripping. Verify the manual reset mechanism operates properly during service checks. Always disconnect power before inspecting or testing the switch.

What are common issues with the York S1-025-31834-000 Limit Switch?

  • Frequent tripping due to furnace overheating conditions.
  • Failure to reset after a high-temperature event.
  • Open switch contacts preventing furnace operation.
  • Intermittent electrical continuity causing system shutdowns.
  • Incorrect temperature sensing resulting in nuisance trips.
  • Damaged terminals or wiring connection failures.

Installation Steps

Step 1: Disconnect power at system and check zero voltage before opening access panel.

Step 2: Remove old limit switch noting wiring positions for correct replacement ensure correct orientation.

Step 3: Mount new switch securely in original placing ensuring firm contact with mounting surface as specified.

Step 4: Reconnect wires to matching terminals and tighten connections.

Step 5: Restore power and test manual reset operate after temperature trip simulation confirm safe operation.