Facebook Pixel

Lennox 14K90 1-1/2 Ton Compressor 208/230V

Special Price $521.76 Regular Price $579.15
Out of stock
SKU
14K90
The Lennox 14K90 Reciprocating Compressor is an essential component of the air conditioners and heat pumps. This is a workhorse of the system and its primary function is to pump refrigerant through the system. To put it in other words it cyclically circulates refrigerant gas taking heat in interior areas and distributing it in the exterior areas. This compressor is intended for single phase electrical supply of 208/230 volts AC with a power frequency of 60 Hz. Constructed from stainless steel, it has a cooling capacity of 1.5 ton (16,300 BTU) and is designed for systems using a 1/4 horsepower motor.
https://www.partshnc.com/media/catalog/product/1/4/14k90.jpg

Specifications

  • Voltage: 208/230V
  • Phase: 1
  • Frequency: 60 HZ
  • Measure: Unit
  • Weight: 61lbs
  • Compressor: Reciprocating
  • Tonnage: 1.5
  • Cooling Capacity: 1.0 Ton Cooling
  • Type: Reciprocating Compressor
  • Capacity: 16300 BTUH
  • Amperage: 48.3AMP

Compressors create the pressure change needed to move refrigerant through a cooling system and support heat transfer during operation. The Lennox 14K90 is an OEM Compressor used in compatible air-conditioning equipment. It provides the compression stage required to move refrigerant through the connected system components. This operation supports the cooling process and helps the equipment maintain its required operating conditions.

COMPRESSOR ROLE IN AIR-CONDITIONING PERFORMANCE:
The compressor is responsible for maintaining refrigerant circulation between the evaporator and condenser. Its operation supports the pressure conditions needed for heat absorption and heat rejection throughout the cooling cycle. In compatible air-conditioning equipment, the Lennox 14K90 performs this essential function as part of the complete refrigeration system. Cooling performance also depends on the condition of the other system components and their ability to support proper heat transfer.

CAPACITY AND EQUIPMENT APPLICATION:
The 1-1/2-ton classification identifies the nominal cooling-capacity category associated with the Lennox 14K90. This rating is useful when identifying a replacement for equipment designed around the corresponding cooling demand. However, compressor selection should not rely on tonnage alone.

REPLACEMENT GUIDELINES:
Replace the 14K90 1-1/2 Ton Compressor when the compressor is confirmed to be faulty or when it can no longer provide the compression required for normal cooling operation. Before ordering, compare the existing compressor's complete part number with the equipment documentation and applicable replacement information.

COMMON SIGNS OF FAILURE:

  • The air-conditioning system fails to maintain the required temperature.
  • The compressor does not start when cooling is requested.
  • Cooling performance decreases during normal operation.
  • Electrical protection repeatedly interrupts compressor operation.
  • Unusual compressor noise or vibration develops.

EQUIPMENT COMPATIBILITY:
The Lennox 14K90 Compressor should be matched to air-conditioning equipment that requires its compressor capacity and electrical characteristics. Before selecting it as a replacement, compare the equipment model and existing compressor identification with the applicable parts documentation.

TECHNICAL SPECIFICATIONS:
Part Identification:
Brand: Lennox
Part Number: 14K90
Capacity Performance:
Cooling Capacity: 1-1/2 Tons
Nominal Cooling Capacity: 18,000 BTU per hour
Electrical Specifications:
Voltage: 208/230V

Write Your Own Review
You're reviewing:Lennox 14K90 1-1/2 Ton Compressor 208/230V
Your Rating
Customer Questions
What should I check if the Lennox 14K90 runs but the air conditioner provides insufficient cooling?

Check refrigerant conditions, airflow, condenser performance, and system controls. These issues can affect cooling without indicating compressor failure.

Can the Lennox 14K90 replace a compressor with a different part number?

Only if the alternative is approved for the equipment and meets its required capacity, electrical, operating, and installation requirements.

Why should I check the original equipment before selecting a 1-1/2-ton replacement?

Equipment with the same nominal capacity can require different compressor configurations. The original equipment identification helps establish the correct replacement.

What could cause the Lennox 14K90 to stop during an operating cycle?

Possible causes include electrical supply problems, control faults, or compressor-related issues. The complete operating circuit should be inspected to identify the cause.

What information helps confirm the correct Lennox 14K90 replacement?

Provide the existing compressor part number, complete equipment model and serial number, and electrical supply details.