Johnson Controls P499RCPS102 Pressure Transducer 0–200 PSI 0.5–4.5 VDC Output

Special Price $206.13 Regular Price $228.81
Out of stock
SKU
P499RCPS102
The Johnson Controls P499RCPS102 Electronic Pressure Output Transducer is a sophisticated instrument in the regulation of pressure information of HVAC systems. It operates in the pressure range between 0 to 200 PSI and provides 0.5VDC to 4.5VDC output signal. This was intended to be an electronic pressure transducer. This uni-directional type is particularly effective in giving accurate pressure measurements to 1% of full scale in liquid or gaseous media.The P499RCPS102 has a 1/4″ NPT connection offering versatility across a number of HVAC applications.
https://www.partshnc.com/media/catalog/product/0/0/0019305_0_4.jpg

Specifications

  • Type: Pressure Transducer
  • Pressure Range: 0–200 PSI
  • Output Signal: 0.5–4.5 VDC

PRODUCT OVERVIEW:
Converts system pressure into an electrical signal to provide pressure-related information to electronic HVAC and refrigeration controls. The Johnson Controls P499RCPS102 Pressure Transducer is an OEM pressure-sensing device that measures pressure within a range of 0–200 PSI and produces a corresponding 0.5–4.5 VDC output. This signal allows the connected control system to interpret pressure conditions and use the information for pressure-dependent monitoring and equipment management functions.

PRESSURE SIGNAL CONVERSION:
Converts applied system pressure into an electrical voltage output that represents the measured pressure condition. The Johnson Controls P499RCPS102 uses this conversion to communicate pressure-related information to the connected electronic control system. Its 0.5–4.5 VDC output provides an electrical signal corresponding to the pressure detected within its specified measurement range.

SYSTEM PRESSURE MONITORING:
Provides electronic equipment controls with pressure-related information for pressure-dependent monitoring functions. The transducer's output allows the receiving controller to interpret changes in system pressure as electrical input signals. This arrangement makes pressure conditions available to the equipment's electronic control process, supporting operating functions that rely on pressure feedback.

REPLACEMENT GUIDELINES:
Replace the Johnson Controls P499RCPS102 Pressure Transducer 0–200 PSI 0.5–4.5 VDC Output when physical damage, internal sensing failure, or electrical deterioration prevents it from providing a reliable pressure signal. A defective transducer may produce inconsistent feedback, fail to communicate pressure information, or interfere with pressure-dependent equipment operation. A qualified HVAC technician should evaluate the transducer and associated electrical connections to determine whether replacement is necessary.

COMMON FAILURE SYMPTOMS:

  • Inconsistent pressure readings from the connected control system.
  • Unstable pressure feedback during equipment operation.
  • Missing pressure information at the electronic controller.
  • Pressure readings that do not correspond with actual system conditions.
  • Irregular equipment operation associated with unreliable pressure signals.

EQUIPMENT COMPATIBILITY:
The Johnson Controls P499RCPS102 OEM Pressure Transducer features a 0–200 PSI measurement range and a 0.5–4.5 VDC output. It is intended for designated HVAC and refrigeration applications requiring these pressure-sensing and electrical output characteristics. Verify the complete equipment model number and existing OEM transducer part number against Johnson Controls manufacturer parts documentation. Confirm the pressure range, output signal, electrical connection, and receiving controller requirements before ordering.

TECHNICAL SPECIFICATIONS:
Brand: Johnson Controls
Part Number: P499RCPS102
Component Type: Pressure Transducer
Pressure Range: 0–200 PSI
Output Signal: 0.5–4.5 VDC

Write Your Own Review
You're reviewing:Johnson Controls P499RCPS102 Pressure Transducer 0–200 PSI 0.5–4.5 VDC Output
Your Rating
Customer Questions
What is the function of the Johnson Controls P499RCPS102 Pressure Transducer?

The Johnson Controls P499RCPS102 measures system pressure and converts it into an electrical signal, allowing connected HVAC or refrigeration controls to receive pressure information.

What equipment details should I verify before purchasing the Johnson Controls P499RCPS102?

Check the original component identification, required pressure range, pressure connection type, and intended equipment application against manufacturer parts documentation.

When should the Johnson Controls P499RCPS102 Pressure Transducer be replaced?

Replacement may be necessary if the transducer is physically damaged, provides inconsistent pressure readings, or fails to deliver a dependable electrical signal. A qualified HVAC technician should confirm the fault.

Why is the electrical output important when selecting a replacement pressure transducer?

The electrical output determines how the connected controller receives pressure information. The replacement signal type and range must match the control system's input requirements.

How can an inaccurate pressure signal affect HVAC or refrigeration equipment?

An inaccurate or missing pressure signal can interfere with control decisions that depend on pressure feedback, potentially disrupting the equipment's intended operation.