The Carriers 48TJ660006 is a heat exchanger with gasket, for Carrier HVAC equipment including furnaces and air conditioners. In cooling mode, refrigerant takes heat from the indoor air across the heat exchanger or the evaporator. In contrast during the heating mode the hot refrigerant begins to relinquish heat to the air stream that is passing through the heat exchanger. This specific heat exchanger has a length of 35 inches, width of 16 inches and a height of 43 inches. The provided gasket guarantees the absence of air leaks and the achievement of the highest possible level of heat exchange.
Manufacturer:
https://www.partshnc.com/media/catalog/product/0/0/0014140_0.jpg

Specifications

  • Length: 35 "
  • Width: 16 "
  • Height: 43 "
  • Weight: 87lbs
  • Type: Heat Exchanger
Manufacturer Name: Carrier
Product Number: 48TJ660006
OEM Part Number: 48TJ660006
Product Description: Heat Exchanger W/Gasket
Weight:87lbs/39462.5g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Carrier 48TJ660006 Heat Exchanger W/Gasket
Your Rating
Customer Questions
What maintenance is required for the Carrier 48TJ660006 Heat Exchanger?

Inspect the heat exchanger periodically for cracks, corrosion, and soot buildup that can reduce heating efficiency. Ensure the gasket remains properly seated and intact to prevent gas leakage. Clean surrounding combustion areas carefully and check proper airflow and venting. Routine checks support maintaining better heat transfer and system accurately.

What are common issues with the Carrier 48TJ660006 Heat Exchanger?

  • Cracks caused by repeated thermal expansion.
  • Soot accumulation restricting heat transfer.
  • Gasket deterioration leading to leakage.
  • Corrosion weakening metal structure.
  • Uneven heating or reduced efficiency.

Installation Steps

Step 1: Turn off power and isolate HVAC system, allow unit to cool and verify zero voltage.

Step 2: Remove access panels and disconnect old heat exchanger and gasket.

Step 3: Clean mounting surfaces and inspect for cracks or corrosion.

Step 4: Install new heat exchanger with gasket, aligning ports and securing bolts to spec.

Step 5: Reconnect electrical and airflow components.

Step 6: Restore power and test for leaks, proper combustion, and better operation.