The Amana-Goodman 2521300S Heat exchanger is used to exchange the heat of the burning gases with the circulating air in the furnace in HVAC systems. It works using a structure made of two sections, where hot gases move through the inside, and a fan pushes air over the outside during the furnace's operation. It is placed in the heating part of the furnace, where the burner directs the combustion gases into the chamber and air flows around the exchanger's walls. This heat, via the chamber surfaces, heats the air circulating, and the gases of combustion.
https://www.partshnc.com/media/catalog/product/2/5/2521300s.jpg
Manufacturer Name: Amana-Goodman
Product Number: 2521300S
OEM Part Number: 2521300S
Product Description: Heat Exchanger 2 Cell
Weight:43.23lbs/19608.78g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Amana-Goodman 2521300S 2-Cell Heat Exchanger
Your Rating
Customer Questions
How to install an expansion valve for refrigeration?

Thermostatic expansion valves are an integral part of your refrigeration unit. They are responsible for ensuring the right dosage of refrigerant is entering the cooling coil to ensure maximum efficiency in the air conditioning of the system.    These special expansion valves come with a temperature sensor that is mounted at the end of the evaporator coil. They incorporate signals from this sensor to maintain the required temperature of the HVAC system. The thermostatic expansion valve works like a precision device that can regulate the measurements of the liquid refrigerant that flows into the evaporator of your system. This regulation in the flow of the refrigerant is essential to prevent the reverse flow of the refrigerant into the compressor of your system.    Through this mechanism, the thermostatic expansion valve successfully separates the high and low pressure sides of the refrigeration/air conditioning system. The liquid refrigerant enters the expansion ...

What maintenance is required for the Amana-Goodman 2521300S Heat Exchanger?

Inspect the heat exchanger regularly for cracks, corrosion, soot accumulation, and signs of overheating. Maintain proper airflow by replacing air filters and keeping vents unobstructed. Check for combustion irregularities that may affect heat transfer performance. Always disconnect power and shut off the gas supply before inspection or service.

What are common issues with the Amana-Goodman 2521300S Heat Exchanger?

  • Soot accumulation reducing heat transfer efficiency.
  • Corrosion in humid or condensate-heavy conditions.
  • Burner misalignment causing uneven flame impingement.
  • Restricted airflow leading to overheating shutdowns.

Installation Steps

Step 1: Turn off power and gas supply; allow furnace to cool completely before starting.

Step 2: Remove furnace access panel and carefully disconnect wiring and mounting hardware from old heat exchanger.

Step 3: Extract old heat exchanger and clean mounting area thoroughly.

Step 4: Install new heat exchanger, aligning properly with brackets and seals.

Step 5: Secure all fasteners, reconnect components, and reassemble panel.

Step 6: Restore power and gas, then test for leaks and proper combustion.