Facebook Pixel

Nordyne 902821 10kW Heat Strip

Special Price $214.00 Regular Price $237.55
In stock
SKU
902821
The Nordyne 902821 Heat Strip 10kW functions as electric heating supplement for HVAC systems. The product functions as an air handler and electric furnace accessory to create heat through electrical resistance during cold weather. This 10kW heat strip provides efficient temperature control which makes it suitable for residential and light commercial use. This product deliver reliable operation and durable design to support indoor comfort through integration with system equipment for better heating result.
Manufacturer:
https://www.partshnc.com/media/catalog/product/9/0/902821_1.jpg
Manufacturer Name: Nordyne
Product Number: 902821
OEM Part Number: 902821
Product Description: 10Kw Heat Strip
Weight:2.62lbs/1188.41g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Nordyne 902821 10kW Heat Strip
Your Rating
Customer Questions
What maintenance is required for the Nordyne 902821 Heat Strip?

Inspect the heat strip assembly for damaged heating elements, loose electrical connections, and signs of overheating during routine HVAC service. Verify that safety limits and wiring connections are functioning correctly. Always disconnect electrical power before servicing the heat strip.

What are common issues with the Nordyne 902821 Heat Strip?

  • Tripped circuit breaker or fuse from electrical overload.
  • Burned out heating elements causing no heat output.
  • Loose or corroded wiring connections leading to intermittent operation.
  • Thermostat malfunction causing inaccurate temperature control.
  • Reduced airflow resulting in uneven heating.

Installation Steps

Step 1: Turn off power at the breaker to ensure safety.

Step 2: Open the unit access panel.

Step 3: Insert the heat strip into the designated slot securely.

Step 4: Connect wiring according to the unit’s wiring diagram.

Step 5: Tighten all terminals and check for loose connections.

Step 6: Reattach the access panel.

Step 7: Restore power and test operation.