Facebook Pixel

York S1-025-47283-000 High Pressure Switch 650/450 PSI

Special Price $75.73 Regular Price $87.09
Out of stock
SKU
S1-025-47283-000
The York S1-025-47283-000 High-Pressure Switch is one of the safety devices used in HVAC systems. It also serves as protective gear to avert system destruction and other risks by working at 650/450 PSI. The pressure switch engages a decoder action if the system pressure goes past a set level, for example, decelerating the compressor or sounding an alert. This is to prevent the equipment from being damaged by pressure buildup. When the pressure goes low, the switch may alert the system to start operating again. This component is essentialfor the safe and proper functioning of HVAC equipment because it is responsible for controlling the system pressure.
https://www.partshnc.com/media/catalog/product/s/1/s1-025-47283-000.jpg

Specifications

  • Type: High Pressure Switch
  • Pressure Range: 650/450 PSI
Manufacturer Name: York
Product Number: S1-025-47283-000
OEM Part Number: S1-025-47283-000
Product Description: 650/450# High Pressure Switch
Weight:0.14lbs/63.5g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:York S1-025-47283-000 High Pressure Switch 650/450 PSI
Your Rating
Customer Questions
What maintenance is required for the York S1-025-47283-000 High Pressure Switch?

Inspect the pressure switch regularly for secure electrical connections and signs of corrosion. Verify pressure settings remain accurate within operating range. Keep the unit clean and dry, and ensure refrigerant system pressures are stable to avoid unnecessary tripping or pressure on the switch components.

What are common issues with the York S1-025-47283-000 High Pressure Switch?

  • Contact failure or electrical switching inconsistency.
  • Refrigerant pressure sensing port clogging.
  • Nuisance tripping under normal operating load.
  • Electrical terminal corrosion leading intermittent signal loss.

Installation Steps

Step 1: Turn off power and recover refrigerant pressure safely.

Step 2: Remove old switch from high-pressure line using proper wrench.

Step 3: Install new switch, ensure correct orientation and tighten fittings.

Step 4: Reconnect wiring terminals as per unit diagram.

Step 5: Restore power and test system operation while checking leaks.