Lochinvar & A.O. Smith 100262938 1” Natural Gas Valve is used in natural gas heating systems. It regulates the amount of natural gas getting to the burner and affords good combustion and heat production. It is designed for compatibility with water heaters, furnaces and boilers manufactured by A.O. Smith and Lochinvar. The precise control of the gas flow that is provided by the valve reduces hazardous emissions, prevents fuel consumption, and ensures temperature regulation. With this valve integrated to your heating system, it provides overall reliability and energy efficiency since it assures adequate gas flows in HVAC system.
Manufacturer:
https://www.partshnc.com/media/catalog/product/1/0/100262938.jpg

Specifications

  • Type: Natural Gas Valve
    Manufacturer Name: Lochinvar & A.O. Smith
    Product Number: 100262938
    OEM Part Number: 100262938
    Product Description: 1" Ng Gas Valve
    Weight:2.02lbs/916.26g

    Choose the best HVAC equipment parts and supplies from PartsHnC!

    • Same Day Shipping

    • Best Quality And Best Price

    • Wide Range of Inventory

    • Best Customer Service

    Have More Questions or Need Help to Place The Order?
    Reach us at (866)773-0907 or [email protected]

    Write Your Own Review
    You're reviewing:Lochinvar & A.O. Smith 100262938 1" Natural Gas Valve
    Your Rating
    Customer Questions
    What maintenance is required for the Lochinvar & A.O. Smith 100262938 Natural Gas Valve?

    Inspect the valve regularly for gas leaks and corrosion. Clean external debris and ensure connections are tight. Check seals and pressure stability during operation. Regular maintenance ensures better gas flow and prevents operational failures in heating systems.

    What are common issues with the Lochinvar & A.O. Smith 100262938 Natural Gas Valve?

    • Gas leakage from worn seals or fittings.
    • Valve sticking or failure to open/close properly.
    • Inconsistent gas flow or pressure drops.
    • Electrical or actuator malfunction affecting operation.
    • Blockage due to debris in gas line affecting valve performance.

    Installation Steps

    Step 1: Shut off gas supply and power, verify no leaks.

    Step 2: Remove old valve and clean pipe threads.

    Step 3: Apply approved pipe thread sealant and install new valve in correct flow direction.

    Step 4: Tighten fittings securely with wrench, avoid over-tightening.

    Step 5: Restore gas slowly and test for leaks using soapy water.