Facebook Pixel

Carrier ZONEXX0DTS01 Zoning System Duct/HP Sensor

Special Price $102.40 Regular Price $117.76
In stock
SKU
ZONEXX0DTS01
The Carrier ZONEXX0DTS01 Zoning-System Duct/HP Sensor is a electronic unit used for temperature control in HVAC zoning systems. This sensor is 3" long, 2" wide, and 0.5" high and is designed for Carrier zoning systems, especially in ducted systems and heat pumps. They deliver this function by governing the fluctuation of temperature at particular zones and therefore improving comfort. This sensor is a useful of saving energy since there are areas that do not need heating of cooling since they are unoccupied. It has small dimensions and can be easily installed, and its high efficiency increases the efficiency of the system as a whole.
https://www.partshnc.com/media/catalog/product/z/o/zonexx0dts01.jpg

Specifications

  • Weight: 0.07lbs
  • Length: 3 "
  • Width: 2 "
  • Height: 0.5 "
Manufacturer Name: Carrier
Product Number: ZONEXX0DTS01
OEM Part Number: ZONEXX0DTS01
Product Description: Zoning System Duct/Hp Sensor
Weight:0.07lbs/31.75g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Carrier ZONEXX0DTS01 Zoning System Duct/HP Sensor
Your Rating
Customer Questions
What maintenance is required for the Carrier ZONEXX0DTS01 Sensor?

Regularly inspect the sensor for dust, debris, and secure connections. Clean the sensing element carefully and verify calibration periodically. Proper maintenance ensures accurate temperature and pressure readings, supporting efficient HVAC operation. Always disconnect power before servicing.

What are common issues with the Carrier ZONEXX0DTS01 Sensor?

  • Inaccurate or fluctuating readings.
  • Loose or faulty electrical connections.
  • Sensor contamination from dust or debris.
  • Erratic HVAC zone responses.

Installation Steps

Step 1: Turn off HVAC power at breaker to prevent electric shock.

Step 2: Locate sensor mounting point on supply or return duct.

Step 3: Secure sensor with screws/clamp ensuring airtight seal.

Step 4: Connect sensor wiring to zoning control board terminals per manual polarity.

Step 5: Restore power and test system operation, checking airflow readings and safety cutoffs.

Step 6: Verify sensor response in zoning panel and ensure no leaks or loose wiring.