The Power Flame Burners X04210 Power Flame Ignitor is an ignition part of HVAC systems, like Power Flame burners, and is compatible with commercial and industrial heating systems. It produces the initial spark/heat to initiate the fuel-air mixture to ensure that the combustion process can begin. It is fitted in the burner assembly, and it runs under the control module and safety circuits to provide a constant ignition. In this ignitor, in terms of maintenance or repair that a constant burner start and constant operation in heating systems is achieved.
https://www.partshnc.com/media/catalog/product/x/0/x04210_power-flame-burners_partshnc.jpg
Manufacturer Name: Power Flame Burners
Product Number: X04210
OEM Part Number: X04210
Product Description: Power Flame Ignitor
Weight:0.13lbs/58.97g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Power Flame Burners X04210 Power Flame Ignitor
Your Rating
Customer Questions
What maintenance is required for the Power Flame Burners X04210 Power Flame Ignitor?

Regularly inspect the ignitor for cracks, carbon buildup, and secure electrical connections. Clean the surface gently and ensure proper alignment with the burner. Proper maintenance ensures accurate ignition and prevents misfires. Always disconnect power before servicing.

What are common issues with the Power Flame Burners X04210 Power Flame Ignitor?

  • Weak or no spark.
  • Cracks or physical damage to the ignitor.
  • Loose or corroded electrical connections.
  • Misalignment causing ignition failure.

Installation Steps

Step 1: Shut off burner power and fuel supply, confirm system is fully de-energized and cooled.

Step 2: Open burner housing and locate existing ignitor assembly.

Step 3: Disconnect electrical leads carefully, noting terminal positions.

Step 4: Remove old ignitor and install new unit in same bracket orientation.

Step 5: Reconnect wiring securely, ensuring proper insulation and grounding.

Step 6: Restore power and fuel, then test ignition cycle.