Facebook Pixel

Resideo WT8840B1000 Water Heater Gas Valve Control 1/2" NPT x 1/2" Inverted Flare 5" WC

Special Price $194.62 Regular Price $223.82
In stock
SKU
WT8840B1000
The Resideo WT8840B1000 Gas Control Trade Replacement Valve is a vital part of the gas water heater, especially for the one with the standing pilot ignition system. This valve is intended to replace the existing valves in the models of AO Smith and Bradford White water heaters and guarantee safe and efficient operation of your appliance. It incorporates an NTC thermistor, to measure the temperature of the water with an enhanced accuracy, to prevent over heating and ensure the better performance is attained. The valve also has a resettable emergency temperature cut off to guard against high temperatures that may be dangerous.
Manufacturer:
https://www.partshnc.com/media/catalog/product/w/t/wt8840b1000.jpg

Specifications

  • Type: Gas Control Valve
  • Connection Size: 1/2" NPT × 1/2" Inverted Flare
  • Pressure Regulator: 5" WC
  • Capacity: 75 BTU
  • DIA: 1"
  • Temperature: 55°F-155°F
  • Voltage: 350 mVDC
  • Sensor Type: NTC Thermistor
  • Ignition Type: Standing Pilot W/Peizo
  • Compatibility: Standing Pilots
Manufacturer Name: Resideo
Product Number: WT8840B1000
OEM Part Number: WT8840B1000
Product Description: Wtrhtrgasvlv55/155F 1"Spud5"Wc
Weight:2.23lbs/1011.51g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Resideo WT8840B1000 Water Heater Gas Valve Control 1/2" NPT x 1/2" Inverted Flare 5" WC
Your Rating
Customer Questions
What maintenance is required for the Resideo WT8840B1000 Gas Control Trade Replacement Valve?

Inspect the valve regularly for gas leaks, corrosion, and loose fittings. Ensure proper cleaning of external surfaces and keep connections tight. Routine servicing to ensure safe operation and consistent gas flow performance.

What are common issues with the Resideo WT8840B1000 Gas Control Trade Replacement Valve?

  • Gas flow inconsistency.
  • Failure to ignite burner.
  • Sticking or jammed valve mechanism.
  • Gas leakage from seals or fittings.
  • Erratic thermostat response.
  • Delayed gas shutoff.

Installation Steps

Step 1: Shut off gas supply and power to water heater; allow cooling.

Step 2: Label and disconnect thermocouple, gas line, and burner connections.

Step 3: Remove old control valve and clean pipe threads thoroughly.

Step 4: Install new valve securely, ensuring correct orientation and sealing.

Step 5: Reconnect gas line and thermocouple per manufacturer diagram.

Step 6: Restore gas supply and check all joints for leaks with soap solution.

Step 7: Light pilot, test burner operation, and check proper temperature control.

Step 8: Ensure adequate ventilation and never use open flame for leak testing.