Facebook Pixel

Metrex Valve WCCW-3060SE 1/2 Inch Npt 2W Wtr Regulator Valve 50/225#Adj

Special Price $749.80 Regular Price $832.28
Out of stock
SKU
WCCW-3060SE

The Metrex Valve WCCW-3060SE is a high-quality 1/2 Inch NPT 2-way water regulator valve designed to provide precise control in HVAC systems. This valve effectively controls the system's water flow, guaranteeing peak efficiency. With a large temperature adjustment range of 50 to 225 degrees Fahrenheit, it provides adaptability to fit the needs of different applications. The valve, which consistently regulates water to maintain ideal temperatures, is a crucial part of HVAC equipment. The entire effectiveness of heating, ventilation, and air conditioning systems is enhanced by its precise adjustment capabilities and sturdy architecture. Customers gain from increased system performance and energy efficiency, which makes the Metrex Valve WCCW-3060SE a wise investment for HVAC applications.

Manufacturer:
https://www.partshnc.com/media/catalog/product/w/c/wccw-3060se_metrex-valve_partshnc.jpg

PRODUCT OVERVIEW:
Water pressure regulation helps maintain controlled flow and protect connected equipment from excessive or fluctuating supply pressure. The Metrex Valve WCCW-3060SE 1/2 Inch Npt 2W Wtr Regulator Valve 50/225#Adj OEM regulates downstream water pressure through an adjustable pressure-control mechanism. Its two-way configuration provides a controlled flow path for compatible water systems.

PRESSURE-ACTUATED VALVE OPERATION:
The valve utilizes an internal pressure sensing mechanism that reacts directly to system pressure. As operating pressure rises, the internal assembly opens the 2-way valve body to increase water flow, and as pressure falls, the valve closes to reduce water passage.

TWO-WAY WATER FLOW CONTROL:
The two-way valve provides an inlet-to-outlet flow path for regulating water delivery. Its internal regulating mechanism adjusts the passage of water to support the required downstream pressure during system operation.

REPLACEMENT GUIDELINES:
Replace the Metrex Valve WCCW-3060SE 1/2 Inch Npt 2W Wtr Regulator Valve 50/225#Adj when it cannot maintain the selected downstream pressure, develops leakage, or causes persistent pressure fluctuations. Internal wear, blockage, or failure of the regulating mechanism may also require replacement. Before installation, verify the original part number, pressure requirements, water-system application, and connection configuration against the equipment documentation

COMMON FAILURE SYMPTOMS:

  • Inability to maintain target condensing pressure due to internal valve wear.
  • Continuous water flow through the condenser when the system is cycling off or de-energized.
  • Restricted cooling water flow leading to high head pressure trips on the refrigeration unit.
  • External water or refrigerant weeping around the valve body, bellows, or adjustment assembly.
  • Mechanical binding or erratic opening caused by scale buildup or debris in the water line.

EQUIPMENT COMPATIBILITY:
The Metrex Valve WCCW-3060SE water regulating valve is designed for select compatible water-cooled refrigeration equipment and HVAC condensing units requiring a 1/2"" NPT 2-way valve with a 50 to 225 PSI adjustment range. Verify brand, part number, valve configuration, inlet/outlet size, connection dimensions, system operating pressures, and fluid compatibility against original equipment documentation prior to installation.

TECHNICAL SPECIFICATIONS:
Product Identification:
Brand: Metrex Valve
Part Number: WCCW-3060SE
Product Type: Two-Way Water Regulator Valve
Connection Details:
Connection Size: 1/2 Inch NPT
Operating Details:
Valve Configuration: Two-Way
Application: Water Pressure Regulation

Write Your Own Review
You're reviewing:Metrex Valve WCCW-3060SE 1/2 Inch Npt 2W Wtr Regulator Valve 50/225#Adj
Your Rating
Customer Questions
What maintenance is required for the Metrex Valve WCCW-3060SE Water Regulator Valve?

Inspect the valve regularly for leaks, corrosion, and pressure irregularities. Clean internal components and filter screens to prevent clogging. Ensure fittings remain tight and pressure settings are calibrated. Follow safety procedures when depressurizing before servicing.

What are common issues with the Metrex Valve WCCW-3060SE Water Regulator Valve?

  • Pressure fluctuations or inconsistent regulation due to internal wear.
  • Valve leakage at seals or connections.
  • Clogging from sediment or debris.
  • Difficulty maintaining set pressure due to calibration drift.
  • Reduced flow performance under high demand conditions.

How does the Metrex WCCW-3060SE valve manage condenser water flow?

The Metrex WCCW-3060SE operates as a pressure-actuated 2-way regulating valve. It senses refrigerant head pressure and dynamically opens or closes to modulate cooling water flow through the condenser within its 50 to 225 PSI setpoint range.

What is the primary function of the Metrex Valve WCCW-3060SE water regulator valve in a water distribution system?

The Metrex Valve WCCW-3060SE regulates water pressure and flow through a connected line to support controlled downstream water delivery.

How does the Metrex Valve WCCW-3060SE adjust water pressure within the system?

Its adjustable regulating mechanism responds to pressure changes and modulates the internal flow passage to maintain the selected pressure setting.

Which piping and pressure requirements determine whether the Metrex Valve WCCW-3060SE is suitable for an existing installation?

Verify the existing valve configuration, 1/2-inch NPT connections, required pressure setting, water service conditions, and piping arrangement against the system specifications.

What regulator conditions can interfere with the Metrex Valve WCCW-3060SE's ability to maintain consistent pressure?

Sediment accumulation, internal wear, damaged regulating components, or restricted passages can interfere with consistent water-pressure regulation.

Installation Steps

Step 1: Turn off the water supply and release system pressure before installation.

Step 2: Confirm the valve matches the pipe size and pressure requirements.

Step 3: Apply thread sealant or tape to the pipe threads.

Step 4: Install the regulator valve in the correct flow direction indicated on the body.

Step 5: Tighten fittings securely without overtightening.

Step 6: Adjust the pressure setting as needed after restoring water flow.

Step 7: Inspect all connections carefully for leaks and proper operation.