Facebook Pixel

Honeywell VS8520E2092/B Central Boiler Fireplace Gas Valve

Special Price $69.99 Regular Price $80.48
Out of stock
SKU
VS8520E2092/B
Honeywell VS8520E2092/B Gas Valve is used in central heating boilers, fireplaces as well as HVAC systems. It controls the rate at which the gas has to get to the burner so as to burn efficiently and safely. We have electrical and mechanical parts in this type of valve through which the flow of the gas is controlled with signals from the thermostat or any other control systems. Originally designed for gas boilers and fireplaces, this valve provides consistent operation, accurate gas regulation for the better heating, and safety against gas leakage and improper ignition.
Manufacturer:
https://www.partshnc.com/media/catalog/product/v/s/vs8520e2092-b_1.jpg

Specifications

  • Type: Fireplace Gas Valve Central Boiler

    Product Overview:
    Designed for fireplace and space-heating equipment, the Honeywell VS8520E2092/B Central Boiler Fireplace Gas Valve is a combination gas valve used within the appliance fuel-control assembly. It provides the connection point between the incoming gas supply and the appliance's burner system while supporting the required control arrangement for the connected equipment. The valve is intended for applications such as gas fireplaces, fireplace inserts, log sets, freestanding stoves, wall furnaces, and room space heaters.

    Gas Passage Control:
    A gas valve controls fuel passage by regulating the opening and closing of the gas path within the appliance. The VS8520E2092/B Gas Valve performs this basic gas-control function within the applicable central boiler fireplace equipment, allowing the valve to control whether gas can pass through the designated gas path during equipment operation.

    Gas Pressure Regulation:
    Gas pressure is controlled through the valve's integrated regulating mechanism as fuel moves toward the burner circuit. The regulator responds to pressure conditions within the controlled fuel path and adjusts the outlet condition as required by the appliance. This provides the connected burner system with the pressure-controlled gas supply specified for the application.

    Replacement Guidelines:
    Replacement may be appropriate when the gas valve no longer performs its intended gas-control function or when the existing valve is identified for replacement as part of equipment service. The replacement part should correspond to the required VS8520E2092/B and the applicable equipment documentation.

    Common Failure Symptoms:

    • Failure of the appliance to operate normally when gas control is required.
    • Inconsistent equipment operation associated with gas delivery.
    • Failure of the combustion system to receive gas as required for operation.
    • Interruption of normal fireplace or boiler operation.

    Equipment Compatibility:
    The Honeywell VS8520E2092/B is intended for compatible gas fireplaces, fireplace inserts, log sets, freestanding stoves, wall furnaces, room space heaters, and other applicable space-heating equipment. The valve is associated with natural gas and LP gas applications and a millivolt control arrangement. Confirm compatibility by matching the equipment model number, serial number, existing valve identification, fuel type, connection configuration, and applicable manufacturer documentation before selection.

    Technical Specifications:
    Brand: Honeywell
    Part Number: VS8520E2092/B
    Product Type: Gas Valve

    Write Your Own Review
    You're reviewing:Honeywell VS8520E2092/B Central Boiler Fireplace Gas Valve
    Your Rating
    Customer Questions
    What maintenance is required for the Honeywell VS8520E2092/B Gas Valve?

    Regularly inspect the valve for gas leaks, corrosion, or debris buildup. Ensure all connections are secure and clean for proper gas flow. Test the valve periodically for smooth operation. Always shut off the gas supply before performing any servicing for safety.

    What are common issues with the Honeywell VS8520E2092/B Gas Valve?

    • Valve not opening or closing properly.
    • Irregular or restricted gas flow.
    • Internal sticking due to wear.
    • Gas leakage at fittings.
    • Delayed or failed ignition response.

    How does the Honeywell VS8520E2092/B Gas Valve control fuel delivery in compatible fireplace equipment?

    The gas valve controls gas passage within the appliance's fuel-delivery system and manages fuel delivery between the incoming gas supply and burner system.

    Why is the Honeywell VS8520E2092/B Gas Valve important to the operation of a central boiler fireplace?

    It serves as part of the appliance's fuel-control arrangement, helping manage the flow of gas to the burner system.

    What problems can occur if the Honeywell VS8520E2092/B Gas Valve does not regulate gas flow properly?

    Improper gas regulation can interfere with the appliance's normal fuel-delivery arrangement and burner operation.

    How can buyers confirm that the Honeywell VS8520E2092/B Gas Valve is compatible with their fireplace?

    Compatibility should be confirmed by comparing the existing valve identification with the fireplace's applicable manufacturer documentation.

    Can the Honeywell VS8520E2092/B Gas Valve be used with natural gas or LP gas?

    A compatible fireplace gas valve can regulate natural gas or LP gas according to the appliance's fuel configuration. The specific fuel configuration should be verified before replacement.

    Installation Steps

    Step 1: Turn off all power and gas supply to the fireplace for safety.

    Step 2: Remove the existing gas valve carefully, noting pipe and wiring connections.

    Step 3: Position the new valve in line with the gas piping.

    Step 4: Secure the valve using proper fittings, ensuring all connections are tight and leak-free.

    Step 5: Reconnect electrical wiring according to manufacturer specifications.

    Step 6: Restore gas and power, then test the fireplace for proper operation and safe ignition.