Facebook Pixel

Trane VAL11798 3-Ton Thermal Expansion Valve (TXV) R410A

Special Price $176.20 Regular Price $202.63
In stock
SKU
VAL11798
The Trane VAL11798 is a Thermal Expansion Valve TXV for use with Trane HVAC systems that use R410A refrigerant and is designed for 3-ton systems. This valve is essentialfor controlling the amount of coolant that circulates within the system at any one time. Think of it as a smart regulating mechanism that observes the flow of the coolant into the evaporator coil. Through its ability to detect temperature and pressure within the coil. Coil-on-coil AC and heat pump systems offer efficient heat absorption which means better cooling capacity and comfort in your house.
Manufacturer:
https://www.partshnc.com/media/catalog/product/v/a/val11798_trane_partshnc.jpg

Specifications

  • Length: 5.09"
  • Weight: 0.95 lbs
  • Size: 3/4 x 3/4"
  • Pressure: 82 PSI
Manufacturer Name: Trane
Product Number: VAL11798
OEM Part Number: VAL11798
Product Description: R410a 3Ton Txv W/Bleed Port
Weight:0.95lbs/430.91g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Trane VAL11798 3-Ton Thermal Expansion Valve (TXV) R410A
Your Rating
Customer Questions
What maintenance is required for the Trane VAL11798 Thermal Expansion Valve?

Inspect the valve periodically for refrigerant leaks and ensure the inlet screen remains clean. Verify superheat settings and adjust calibration as needed for stable operation. Proper maintenance prevents inefficiency, flow restriction, and system performance issues. Always handle refrigerant safely.

What are common issues with the Trane VAL11798 Thermal Expansion Valve?

  • Refrigerant flow restriction due to clogging or debris.
  • Improper superheat control causing poor cooling performance.
  • Valve sticking or hunting leading to unstable operation.
  • Sensor bulb failure or poor contact affecting regulation.
  • Evaporator underfeeding or overfeeding causing icing or inefficiency.

Installation Steps

Step 1: Turn off power and safely recover refrigerant using proper equipment.

Step 2: Access the evaporator coil and locate the existing old valve.

Step 3: Disconnect sensing bulb, equalizer line, and refrigerant connections.

Step 4: Remove the old valve and install the new thermal expansion valve, ensuring proper orientation.

Step 5: Secure and insulate the sensing bulb on the suction line.

Step 6: Evacuate system, recharge refrigerant, restore power, and test operation for leaks and performance.