Facebook Pixel

Trane VAL11154 Thermal Expansion Valve (TXV) R410 Chatleff

Special Price $151.16 Regular Price $173.83
In stock
SKU
VAL11154
The Trane VAL11154 is a Thermal Expansion Valve (TXV) suitable to be utilized in systems utilizing R410A refrigerant primarily in HVAC systems. Another thing about the Trane is that it can be adjusted, so you can regulate the amount of refrigerant that flows in your system based on the specific needs of your HVAC system. The Trane has leakproof connections with Chatleff connections and the working pressure of the unit is 133.8 psi. It increases the reliability and efficiency of your R410A HVAC system as the Trane directly measures the refrigerant flow as per the system requirement which enhances the evaporator coil performance.
Manufacturer:
https://www.partshnc.com/media/catalog/product/v/a/val11154.jpg

Specifications

  • Weight: 1.02lbs
  • Length: 4.6"
  • Capacity: 3 (Ton)
  • Connection Size: 3/4 x 7/4"
  • Type: Adjustable
  • Working Pressure: 133.8 (PSI)
  • Flow Control: 15% Bleed
  • Connection Type: Chatleff
Manufacturer Name: Trane
Product Number: VAL11154
OEM Part Number: VAL11154
Product Description: R410 Txv Chatleff
Weight:1.02lbs/462.66g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Trane VAL11154 Thermal Expansion Valve (TXV) R410 Chatleff
Your Rating
Customer Questions
What maintenance is required for the Trane VAL11154 Thermal Expansion Valve?

Regularly inspect the valve for leaks, corrosion, or debris buildup. Ensure proper refrigerant charge and clean surrounding components to maintain efficiency. Periodic system checks help prevent pressure imbalances. Always follow safety procedures when handling refrigerants or servicing HVAC systems.

What are common issues with the Trane VAL11154 Thermal Expansion Valve?

  • Improper refrigerant flow regulation causing poor cooling performance.
  • Valve sticking or failing to open and close correctly.
  • Internal blockage due to contaminants or debris.
  • Incorrect superheat settings leading to system inefficiency.

Installation Steps

Step 1: Turn off HVAC power and recover refrigerant safely.

Step 2: Remove access panel and disconnect the old valve from evaporator coil.

Step 3: Install new valve, ensuring fittings are properly aligned and sealed.

Step 4: Braze connections using purge to prevent oxidation inside lines.

Step 5: Perform pressure test, leak check, evacuate system to deep vacuum.

Step 6: Recharge refrigerant to spec and verify superheat and system operation.