Trane CNT5133 Single Stage Ignition Control Board

Special Price $216.02 Regular Price $239.79
Out of stock
SKU
CNT5133
The Trane CNT5133 single-stage ignition control board Trane or American Standard gas heating systems. This board is responsible for the safe and proper lighting of the furnace in this place. During the heating cycles, this initiates the gas burner ignition sequence through the use of direct spark technology. The control board fires the igniter electrode with a high-voltage spark once your thermostat senses the need for heat. This spark initiates the burning process that warms your house by burning a gas that is dripping from the burner valve. A working ignition control board is required for the house to be comfortable all through.
Manufacturer:
https://www.partshnc.com/media/catalog/product/0/0/0018560_0_3.jpg

Specifications

  • Weight: 0.89 lbs
  • Type: Direct Spark, Single Stage
Manufacturer Name: Trane
Product Number: CNT5133
OEM Part Number: CNT5133
Product Description: 1Stg Ignition Control Board
Weight:0.89lbs/403.7g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Trane CNT5133 Single Stage Ignition Control Board
Your Rating
Customer Questions
How to install an expansion valve for refrigeration?

Thermostatic expansion valves are an integral part of your refrigeration unit. They are responsible for ensuring the right dosage of refrigerant is entering the cooling coil to ensure maximum efficiency in the air conditioning of the system.    These special expansion valves come with a temperature sensor that is mounted at the end of the evaporator coil. They incorporate signals from this sensor to maintain the required temperature of the HVAC system. The thermostatic expansion valve works like a precision device that can regulate the measurements of the liquid refrigerant that flows into the evaporator of your system. This regulation in the flow of the refrigerant is essential to prevent the reverse flow of the refrigerant into the compressor of your system.    Through this mechanism, the thermostatic expansion valve successfully separates the high and low pressure sides of the refrigeration/air conditioning system. The liquid refrigerant enters the expansion ...

Please, mind that only logged in users can submit questions