Detroit Radiant TP-240 3.5" Natural Gas Valve W/Burner 120V
Specifications
- Type: Natural Gas Valve W/Burner
- Size: 3.5"
- Voltage: 120V
Loyalty ProgramProduct Overview:
Provides integrated natural gas control and burner operation. The Detroit Radiant TP-240 3.5" Natural Gas Valve With Burner regulates fuel delivery to the connected burner according to the heater's control sequence. Its assembly combines gas valve control, pressure regulation, and burner operation within the fuel-delivery system. The 120V electrical configuration supports valve actuation during the heating cycle.
Natural Gas Flow Control:
Regulates natural gas passage through the valve assembly according to the heater's operating requirements. The valve controls fuel delivery toward the connected burner, establishing the gas supply required for combustion during an active heating cycle.
Burner Integration:
Connects gas valve operation with the associated burner assembly within the heater's fuel train. The valve establishes the fuel-delivery condition required for burner operation, allowing gas admission and burner combustion to operate as part of the same heating sequence.
Replacement Guidelines:
Replacing the Natural Gas Valve W/Burner is appropriate if it is damaged, malfunctioning, excessively worn, or otherwise deteriorated. Verify the DETROIT RADIANT part number TP-240 and the complete heating equipment model number before replacement. Replace the assembly if deterioration affects gas control, burner operation, pressure regulation, electrical actuation, or normal heating performance.
Common Signs of Wear:
Equipment Compatibility:
The Detroit Radiant TP-240 3.5" Natural Gas Valve With Burner is intended for heating equipment that specifies part number TP-240. Verify the complete equipment model number, natural gas requirement, 3.5" WC pressure specification, 120V control requirement, and manufacturer's parts documentation before purchasing to help confirm the correct application.
Technical Specifications:
Brand: Detroit Radiant
Part Number: TP-240
Product Type: Natural Gas Valve with Burner
Gas Size: 3.5"
Voltage: 120V
Step 1: Turn off gas supply and electrical power; check system is fully isolated.
Step 2: Remove heater access panel and label all wiring and gas connections.
Step 3: Disconnect control wiring and unthread gas inlet/outlet fittings.
Step 4: Remove old valve/burner assembly and clean connection points.
Step 5: Install new unit in correct orientation, ensuring proper alignment with burner.
Step 6: Reconnect gas lines using approved sealant and tighten securely.
Step 7: Reconnect wiring, restore power and gas, then test ignition and check for leaks.