The Utica-Dunkirk 240007071 Tankless Coil Gasket is a sealing part that is used in HVAC systems. It gives a seal between the coil and the system around it to avoid water or steam leaks and to ensure that the heat is transferred efficiently. The gasket is installed either in the assembly or maintenance and to ensure the steady performance and stable operation. It is apt in residential and commercial heating systems and helps to increase boilers and tankless water heaters in terms of energy efficiency.
https://www.partshnc.com/media/catalog/product/2/4/240007071.jpg
Manufacturer Name: Utica-Dunkirk
Product Number: 240007071
OEM Part Number: 240007071
Product Description: Tankless Coil Gasket
Weight:0.1lbs/45.36g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Utica-Dunkirk 240007071 Tankless Coil Gasket
Your Rating
Customer Questions
What maintenance is required for the Utica-Dunkirk 240007071 Tankless Coil Gasket?

Regularly inspect the gasket for cracks, compression, or leaks, especially during heating season. Clean surrounding surfaces before installation or reinstallation to ensure a proper seal. Replace immediately if damaged to prevent water leaks, corrosion, or system inefficiency.

What are common issues with the Utica-Dunkirk 240007071 Tankless Coil Gasket?

  • Gasket cracking or splitting.
  • Leaks around coil connections.
  • Improper sealing causing water bypass.
  • Deformation from heat or pressure.

Installation Steps

Step1: Turn off power and water supply to the boiler to prevent injury.

Step2: Drain the system if necessary to access the tankless coil.

Step3: Remove the old gasket carefully and clean the sealing surface.

Step4: Position the tankless coil gasket correctly on the coil or mounting flange.

Step5: Ensure proper alignment to prevent leaks.

Step6: Reassemble the coil and any components removed during installation.

Step7: Restore water supply and power, and test the system for leaks and proper operation.