Resideo T104B1046 High-Capacity Thermostatic Radiator Actuator 16' Capillary

Special Price $172.63 Regular Price $198.53
In stock
SKU
T104B1046
The Resideo T104B1046 High Capacity Thermostatic Radiator Actuator is a highly developed part that enhances your heating system. This actuator regulates the radiator temperatures with the help of a remote sensor and a 16 ft capillary tube which makes it ideal for hot water or steam radiators. It has a temperature control range of 48°F to 79°F, which makes it have temperature control. The actuator has a cast brass body with nickel plating to make it strong and it has a set point dial for ease of setting. This one can be mounted on the wall and has a steady temperature regulation when combined with the V110 Series.
https://www.partshnc.com/media/catalog/product/t/1/t104b1046.jpg

Specifications

  • Type: Thermostatic Radiator Actuator
  • Application: Radiator Accessory
  • Color: White
  • Includes: Sensor, Setpoint Dial, Valve Actuator
  • Compatible With: Hot Water, Steam
  • Temperature Range: 48°F to 79°F
  • Capillary Tube Length: 16ft
  • Body Material: Cast Brass
  • Finish: Nickel-Plated
  • Used With: V110 Series
  • Mount: Wall
  • Sensor Type: Remote
  • Setpoint: Remote
  • Diameter: 1-19/32"

Product Overview:
Regulates radiator heating output through temperature-responsive actuation of the connected radiator valve. The Resideo T104B1046 Thermostatic Radiator Actuator High-Capacity 16' CAP is an OEM thermostatic control component featuring a 16-foot capillary for remote temperature sensing. Its separated sensing arrangement allows the actuator to respond to thermal conditions measured away from the actuator body and adjust the connected valve accordingly.

Remote Sensing:
Establishes the point at which the thermal condition is measured within the control arrangement. The sensing element is positioned separately from the actuator body so the control can obtain temperature information from a designated location. Its role is centered on the placement and response of the sensing element, allowing the control system to use conditions at that location as its temperature reference rather than relying on the immediate environment surrounding the actuator.

Capillary Control:
Provides the physical sensing connection between the remote element and the actuator mechanism. The capillary maintains the link required for the sensing assembly to influence the actuator without placing the primary sensing element directly at the control body. Its function centers on maintaining this separated connection and enabling the actuator mechanism to receive the thermal input generated by the remote sensing arrangement.

Replacement Guidelines:
Replace the Resideo T104B1046 Thermostatic Radiator Actuator High-Capacity 16' CAP when the existing radiator actuator has deteriorated, has been removed during service, or no longer provides adequate temperature control. Renew the actuator during applicable maintenance or component replacement to restore the required temperature-regulating function and support proper radiator operation.

Common Failure Symptoms:

  • Temperature response becomes inconsistent during changes.
  • Valve movement becomes irregular during adjustment.
  • Actuator response becomes restricted during changes.
  • Temperature regulation becomes unstable across the radiator.
  • Physical deterioration develops on the actuator body.

Equipment Compatibility:
The Resideo T104B1046 Thermostatic Radiator Actuator High-Capacity 16' CAP is intended for use with applicable thermostatic radiator valve arrangements requiring temperature-responsive control of radiator heating output. Its application depends on the associated radiator valve and system configuration. Always verify the T104B1046 equipment model number and manufacturer's parts documentation before purchasing.

Technical Specifications:
Brand: Resideo
Part Number: T104B1046
Product Type: Thermostatic Radiator Actuator High-Capacity
Capillary Length: 16'

Write Your Own Review
You're reviewing:Resideo T104B1046 High-Capacity Thermostatic Radiator Actuator 16' Capillary
Your Rating
Customer Questions
What is the Resideo T104B1046 remote-sensing actuator used for?

It enables radiator control based on temperature measured away from the actuator.

Where does a remote-sensing actuator measure temperature?

It detects temperature at a designated remote point rather than at the actuator itself.

What is the function of the capillary in remote temperature sensing?

The capillary connects the remote sensing element to the actuator assembly.

How does remote temperature sensing affect radiator control?

The sensed temperature provides input for the actuator to adjust the connected radiator valve.

How should a remote-sensing radiator actuator be inspected?

Check the capillary for visible damage and inspect the actuator for restricted movement. Follow the manufacturer's service instructions for further checks.