Facebook Pixel

Rheem-Ruud SP12258B Gas Control Valve (Thermostat) - LP 160°F

Special Price $352.12 Regular Price $390.86
Out of stock
SKU
SP12258B
The Rheem-Ruud SP12258B Gas Control Valve Thermostat controls flow and regulating liquid propane (LP) in heating systems, offering precise temperature and optimum operating. This gas control valve has a temperature range of up to 160°F and fits smoothly with HVAC systems to control propane fuelled equipment’s ignition and combustion processes. This thermostatic gas control valve is essential to keeping propane powered furnaces, heaters, and other heating appliances at peak performance and safety. It regulates gas flow depending on the setting temperature in order to keep the heat production neutral but reduce overheating.
https://www.partshnc.com/media/catalog/product/s/p/sp12258b_rheem-ruud_partshnc.jpg

Specifications

  • Temperature Range: 160°F
  • Type: Gas Control Valve (Thermostat)
  • Fuel Type: Liquid Propane (LP)
  • Weight: 1.96 Lbs

Product Overview:
Gas-fired water heaters require accurate temperature regulation and controlled fuel delivery for proper burner operation. The Rheem-Ruud SP12258B Gas Control Valve (Thermostat) - LP 160°F is a genuine OEM gas control assembly designed for specified Rheem and Ruud liquid propane water heater applications. It combines thermostat regulation and gas-flow control to maintain selected water temperatures, with an adjustable range up to 160°F.

Gas Control and Temperature Regulation:
The thermostat senses water temperature inside the storage tank and controls the gas supply to the main burner. This temperature-responsive operation regulates burner cycling according to the selected setting.

Gas Connection and Burner Control:
The assembly regulates liquid propane delivery through its gas inlet and burner outlet connections. Its configuration includes a left-hand main burner outlet and a thermostat shank designed for the specified water heater installation.

Replacement Guidelines:
Replace the Rheem-Ruud SP12258B when water temperature regulation becomes unreliable, the main burner fails to operate correctly, or the valve no longer controls gas flow in response to thermostat settings. Replacement may also be necessary if the control develops a gas leak or its internal temperature-sensing mechanism malfunctions. Have a qualified gas appliance technician handle installation, verify the LP gas connections, and test burner and pilot operation.

Common Signs of Wear:

  • Water temperature does not remain near the selected setting.
  • Burner fails to operate according to temperature demand.
  • Water heater experiences inconsistent heating.
  • Thermostat adjustment becomes unresponsive.
  • Visible damage or deterioration appears around gas connections.

Equipment Compatibility:
The Rheem-Ruud SP12258B Gas Control Valve (Thermostat) - LP 160°F is an OEM replacement for selected Rheem and Ruud water heaters designed for liquid propane. It is listed for specific LP gas control applications and must not be installed in natural gas equipment or used for fuel conversion. Compare the existing control and appliance identification numbers before ordering to confirm the correct replacement.

Technical Specifications:
Manufacturer: Rheem-Ruud
Part Number: SP12258B
Product Type: Gas Control Valve with Thermostat
Maximum Temperature Control: 160°F

Write Your Own Review
You're reviewing:Rheem-Ruud SP12258B Gas Control Valve (Thermostat) - LP 160°F
Your Rating
Customer Questions
What is the Rheem-Ruud SP12258B gas control valve used for?

It regulates water temperature in compatible liquid propane water heaters. The assembly controls gas flow to the main burner according to the selected temperature setting.

How does this LP gas control thermostat regulate water heating?

Its temperature-sensing mechanism responds to water temperature inside the tank. The gas valve controls burner operation to maintain the selected temperature.

Which fuel type is this gas control valve designed for?

It is specifically designed for liquid propane (LP) water heaters. It is not intended for natural gas applications.

What temperature and heating capacity specifications does this valve offer?

It has an adjustable temperature range of 57°F to 160°F and a maximum heating capacity of 38,000 BTU per hour. It also includes a 200°F high-limit safety cutoff.

What safety feature is included in the Rheem-Ruud SP12258B gas control valve?

It incorporates a high-limit safety cutoff that interrupts gas flow when water temperature reaches the specified safety threshold. This feature adds temperature protection to the water-heating system.