The York S1-FHM3595 is a versatile blower motor that has 1 horsepower and three speeds that it can operate in HVAC systems. This motor operates at 1075 RPM at 115V and 60 Hz of frequency and has been developed for use in applications that demand accuracy and longevity. Due to the unique characteristic of the reversible rotation, which allows for the versatile installation and operation of the product, it can be applied both to the furnace blower assemblies and air handling systems. This motor has three-speed controls that enable the user to control the amount of airflow that is required for heating and cooling.
https://www.partshnc.com/media/catalog/product/s/1/s1-fhm3595-york_partshnc.jpg

Specifications

  • Type: Blower Motor
  • Voltage: 115 V
  • Speed: 1075 RPM
  • Frequency: 60 Hz
  • Phase: 1 PH
  • Rotation: Reversible
  • No of Speeds: 3
Manufacturer Name: York
Product Number: S1-FHM3595
OEM Part Number: S1-FHM3595
Product Description: 115V 1Hp 1075Rpm 3Spd Motor
Weight:20.51lbs/9303.17g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:York S1-FHM3595 1HP 3-Speed Blower Motor 1075RPM 115V
Your Rating
Customer Questions
What maintenance is required for the York S1-FHM3595 Blower Motor?

Clean the motor and fan assembly regularly to prevent dust buildup. Inspect electrical connections for looseness or corrosion. Lubricate bearings if applicable. Regular maintenance ensures efficient airflow, reduces overheating risk, and improves motor performance safety.

What are common issues with the York S1-FHM3595 Blower Motor?

  • Motor overheating due to blocked airflow or dust accumulation.
  • Inconsistent speed due to faulty capacitor or switch.
  • Excessive vibration from worn bearings or unbalanced fan.
  • Electrical failure or intermittent operation from wiring issues.

Installation Steps

Step 1: Turn off power at breaker and verify no voltage.

Step 2: Ensure correct replacement match and wear insulated gloves for safety.

Step 3: Remove access panel, disconnect and label existing wiring, then take out the old blower motor carefully from housing.

Step 4: Mount motor securely, align shaft with blower wheel, and tighten brackets without over-torquing.

Step 5: Reconnect wiring per diagram, ensure proper grounding, restore power, and test for smooth, vibration-free operation.