Facebook Pixel

York S1-6008080 3/4HP Condenser Motor 1110 RPM 460V/1PH

Special Price $398.46 Regular Price $442.30
In stock
SKU
S1-6008080
This York S1-6008080 3/4-HP Condenser Motor is an efficient unit designed to provide effective services in HVAC systems. This condenser fan motor has a power of 3/4 horsepower, rotates at 1110 RPM, and requires a 460V single-phase supply. With a counterclockwise rotation with the lead end (CCWLE), the motor optimizes the airflow and cools condenser units to their . It has an amperage of 1.6 and comes with ball bearings for long-lasting use and ease of operation. The number 48Y in the frame size suggests a robust frame design suitable for most HVAC applications. It is used in air conditioning units /heat pumps and has demand for the operation of condenser functions.
Manufacturer:
https://www.partshnc.com/media/catalog/product/s/1/s1-6008080.jpg

Specifications

  • Type: Condenser Fan Motor
  • Speed RPM: 1110 RPM
  • Rotation: CCWLE
  • Amperage Rating: 1.6 A
  • Bearing Type: Ball
  • Horsepower: 3/4 HP
  • Phase: 1
  • Voltage: 460V
  • Bearing Type: Ball
  • Frame Size: 48Y
Manufacturer Name: York
Product Number: S1-6008080
OEM Part Number: S1-6008080
Product Description: 460V1ph 3/4Hp 1110Rpm Cond Mtr
Weight:18.39lbs/8341.56g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:York S1-6008080 3/4HP Condenser Motor 1110 RPM 460V/1PH
Your Rating
Customer Questions
What maintenance is required for the York S1-6008080 Condenser Motor?

Regularly inspect the motor for dust, debris, and secure electrical connections. Lubricate bearings if applicable and check for proper mounting alignment. Ensure ventilation is clear to prevent overheating. Proper maintenance ensures smooth operation and prevents noise or performance issues.

What are common issues with the York S1-6008080 Condenser Motor?

  • Overheating during operation.
  • Bearing wear or failure.
  • Excessive vibration or noise.
  • Electrical connection problems.

Installation Steps

Step 1: Turn off and disconnect all power to the HVAC unit before starting.

Step 2: Remove the condenser fan assembly to access the old motor.

Step 3: Disconnect wiring from the old motor, noting original connections.

Step 4: Loosen mounting bolts and remove the old motor.

Step 5: Position the new motor on the mount and secure bolts.

Step 6: Reconnect wiring according to the original configuration.

Step 7: Reinstall the fan assembly, restore power, and test for proper operation and smooth rotation.