S1-031-02996-000
The York S1-031-02996-000 is a crucial component of a heat pump system; it is the central of the system. This one-stage control board is accountable for the heating and cooling cycles as it guarantee. It crucial to maintaining comfort inside the house. The compressor, fan and reversing valve of the heat pump are some of the parts that the control board instructs to run in order to coordinate this process. It receives signals the compressor is turned on to circulate refrigerant from the control board.
https://www.partshnc.com/media/catalog/product/S/1/S1-031-02996-000_york_partshnc.jpg

Specifications

  • Type: Heat Pump Control Board
  • Stage Type: 1
  • Dimension: 9.3" X 8.3" X 2.7"
  • Compatibility: Various York Heat Pump MModels
  • Weight: 0.44lbs
Manufacturer Name: York
Product Number: S1-031-02996-000
OEM Part Number: S1-031-02996-000
Product Description: 1Stg Heat Pump Control Board
Weight:0.44lbs/199.58g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:York S1-031-02996-000 1-Stage Heat Pump Control Board
Your Rating
Customer Questions
What maintenance is required for the York S1-031-02996-000 Heat Pump Control Board?

The control board should be inspected periodically for loose wiring, corrosion, or burnt components. Keep the HVAC cabinet clean and dry to prevent moisture damage. Ensure proper voltage protection and check connections during routine servicing.

What are common issues with the York S1-031-02996-000 Heat Pump Control Board?

  • Relay failure causing no start or intermittent operation.
  • Burnt components due to power surges or overheating.
  • Communication errors with thermostat or HVAC system.
  • Unresponsive board leading to complete system shutdown.

Installation Steps

Step 1: Turn off power at breaker and verify no voltage ensure thermostat off.

Step 2: Remove access panel and safely discharge capacitors to avoid shock.

Step 3: Label and disconnect wiring harnesses carefully and note positions.

Step 4: Remove old control board from mounting bracket screws.

Step 5: Install new control board securely on bracket align connectors properly.

Step 6: Reconnect wiring per manufacturer diagram tighten all terminals.

Step 7: Restore power and test heat pump operation.