Resideo RRD8 Retrofit Round Damper 8" 24V

Special Price $183.87 Regular Price $211.45
In stock
SKU
RRD8
The Resideo RRD8 Trol-A-Temp is a motorized damper that is utilized to control the airflow in a duct system. It is specifically designed for retrofit applications and will slide into standard 8 inch round ductwork with relative ease. This damper is part of the zoning system that makes it possible to regulate temperature in different parts of a house or a building. The RRD8 is designed to use a power open/power close motor and it opens or closes in approximately 90 seconds. It is constructed with galvanized steel hence it is strong and is not liable to rust. Several dampers can be interfaced with a zone control system and yet only draw 1.5W of power. The leakage rate of 3.4 % at a 0.5” water column of the damper provides a strong seal for air distribution.
https://www.partshnc.com/media/catalog/product/r/r/rrd8.jpg

Specifications

  • Type: Retrofit Zone Damper
  • Size: 8"
  • Motor Type: Power Open/Close
  • Motor Timing: 90 seconds
  • No of Wires To Motor: 3
  • Voltage: 24 VAC
  • Material: Galvanized Steel
  • Power: 1.5W
  • Closing Time: 90 seconds
  • Torque: 5Nm
  • Leakage Rate: 3.4% at 0.5"-WC

Product Overview:
Regulates airflow through a round duct in a zoned HVAC system by adjusting the damper position. The Resideo RRD8 8" 3-Wire Retrofit Round Damper is an OEM airflow-control component featuring an 8-inch round configuration, a three-wire connection, and a floating actuator. Its retrofit design supports damper installation in HVAC zoning applications requiring the corresponding round-damper and actuator configuration.

Airflow Regulation:
Controls airflow through the connected round duct by moving the damper blade between open and closed positions. The 24V power-open/power-close actuator changes the blade position according to commands from the connected zoning control system. The actuator automatically stops when the blade reaches the full-open or full-closed position, providing defined operating positions within the damper assembly.

Zone Air Distribution:
Within a forced-air zoning system, the damper controls the conditioned-air path serving its assigned zone. Its operation coordinates with the connected zoning panel to regulate air distribution through the applicable branch duct. The mechanical blade position indicator provides a visible reference of blade position, while the adjustable range stops establish the available blade movement.

Replacement Guidelines:
Replace the Resideo RRD8 Trol-A-Temperature 8" Retrofit Zone damper when the blade fails to move correctly, the actuator no longer responds to the zoning control, or the assembly shows physical damage. Before selecting a replacement, verify the duct diameter, 24V requirement, power-open/power-close motor configuration, three-wire motor arrangement, and applicable zoning-panel requirements.

Common Signs of Wear:

  • Damper blade fails to open or close as expected.
  • Actuator does not respond to zoning control commands.
  • Unusual noise occurs during actuator operation.
  • Damper or actuator shows visible physical damage.
  • Airflow remains restricted when the damper should be open.

Equipment Compatibility:
The RRD8 is intended for compatible forced-air zoning systems using 8-inch rigid round ductwork. It is specified for retrofit zone-damper applications and is compatible with Resideo zoning panels. The damper is applicable to heating and cooling zones where the connected zoning system requires controlled airflow through an 8-inch round branch duct.

Technical Specifications:
Brand: Resideo
Part Number: RRD8
Product Type: Retrofit Round Damper
Damper Size: 8 in.
Wire Configuration: 3-Wire
Actuator Type: Floating Actuator

Write Your Own Review
You're reviewing:Resideo RRD8 Retrofit Round Damper 8" 24V
Your Rating
Customer Questions
What is the RRD8 retrofit zone damper used for?

The RRD8 controls airflow in compatible forced-air HVAC zoning applications using a 24V power-open/power-close actuator.

What should I verify before selecting the RRD8 zone damper?

Check the required damper size, duct configuration, 24V actuator requirements, three-wire motor arrangement, and zoning-panel compatibility against the equipment documentation.

What problems may indicate that a zone damper is not operating correctly?

A zone receiving insufficient airflow or a damper that fails to reach the commanded position may indicate an actuator, wiring, or control-system issue.

When should the RRD8 zone damper be replaced?

Consider replacement if the damper or actuator is damaged or fails to control airflow as intended after appropriate troubleshooting.

What maintenance is appropriate for a motorized zone damper?

During scheduled HVAC servicing, have a qualified technician check the damper blade, actuator, wiring, and mounting for obstructions, wear, or visible damage.