York S1-025-47289-000 Reversing Valve

Special Price $185.17 Regular Price $212.94
In stock
SKU
S1-025-47289-000
The York S1-025-47289-000 Reversing Valve is one of the critical components in HVAC systems, especially heat pumps. This is a rather durable valve made of brass through which the refrigerant can be controlled to switch from a heating mode to a cooling mode effortlessly. It reverses the functionality of the heat pump regarding the refrigerant direction and thus provides warmth during the winter as well as cooling during the summer. This flexibility enhances energy conservation and comfort conditions for the occupants. This reversing valve is designed for York HVAC equipment to guarantee optimum performance and reliability.
Manufacturer:
https://www.partshnc.com/media/catalog/product/s/1/s1-025-47289-000.jpg

Specifications

  • Type: Reversing Valve
  • Material: Brass
  • Application: HVAC Systems, Specifically Heat Pumps

PRODUCT OVERVIEW:
Heat pumps rely on refrigerant direction changes to transition between heating and cooling operation. The York S1-025-47289-000 Reversing Valve is a genuine OEM 4-way electromechanical switching valve engineered to redirect high-pressure refrigerant through specified heat pump systems. It manages the designated flow path between the indoor and outdoor heat exchangers to alter system operating modes.

REFRIGERANT OPERATION:
The 4-way valve manages heating and cooling transitions via an active pilot-operated mechanism. When the thermostat calls for a mode change, a 24V current energizes the solenoid coil to actuate a small pilot valve plunger. This action redirects pilot capillary pressures, utilizing the system's own high-and-low pressure differentials to physically slide the main internal block. The slider then alters the path of the main high-pressure gas stream, changing the outdoor coil between an evaporator and a condenser while sealing tightly to prevent thermal cross-bleeding.

REPLACEMENT GUIDELINES:
Replace York S1-025-47289-000 when parts documentation identifies that the existing 4-way valve has developed severe internal bypass leaks, a seized slider, or an electrical coil failure. Prior to servicing, isolate all electrical power, safely reclaim the system's entire refrigerant charge, and maintain a dry nitrogen purge to protect internal components. Because this installation requires high-temperature copper brazing near heat-sensitive internal seals, this replacement must be performed by a qualified technician.

COMMON FAILURE SYMPTOMS:

  • Heat pump remains permanently stuck in one operating mode.
  • Drop in system efficiency due to hot gas bleeding directly into the suction line.
  • Absence of an audible clicking sound from the solenoid coil when voltage is applied.
  • Visible compressor oil residue tracking around the copper connections.

EQUIPMENT COMPATIBILITY:
The York S1-025-47289-000 is an official OEM replacement reversing valve assembly precision-matched for designated York heat pump equipment. Port configurations and internal capacities depend entirely on matching your system's exact design specifications. You must verify the model number of the product with the equipment documentation to ensure exact compatibility before purchase.

TECHNICAL SPECIFICATIONS:
Product Identification:
Brand: York / Johnson Controls
SKU: S1-025-47289-000
Part Number: S1-025-47289-000
Product Type: Reversing Valve (4-Way Valve)
Equipment Type: Heat Pump Systems
Valve Operation & Control:
Control Type: Pilot-Operated Solenoid 4-Way Directional Control
Component Status: Genuine OEM Replacement Part

Write Your Own Review
You're reviewing:York S1-025-47289-000 Reversing Valve
Your Rating
Customer Questions
What does the York reversing valve do in a heat pump?

The York S1-025-47289-000 alternates the flow of high-pressure refrigerant to switch your system between heating and cooling cycles.

Does this York reversing valve assembly include the solenoid coil?

Yes, this genuine OEM replacement part comes complete with a pre-matched 24V solenoid coil required to actuate the pilot shifting mechanism.

What are the signs of a bad heat pump reversing valve?

Common symptoms include a system stuck in a single mode, reduced efficiency from internal thermal cross-bleeding, or a non-responsive electrical coil.

Does this 4-way valve require professional installation?

Yes, because replacing this valve requires complete refrigerant recovery and high-temperature copper brazing, the task must be completed by a qualified technician.