Facebook Pixel

Resideo SV9501M2700/B Peerless Smart Gas Valve

Special Price $265.65 Regular Price $294.88
In stock
SKU
SV9501M2700/B
The Resideo SV9501M2700/B Peerless Smart Gas Valve is designed to provide accurate and dependable control of natural gas flow in HVAC systems. It controls the supply of gas through the intermittent hot surface pilot ignition for safety and effectiveness. It opens in a standard sequence and provides a controlled gas flow through its straight-through construction with NPT ports. It is intended for furnaces and boilers and has an operating range of -40°F to 175°F at 50/60 Hz. It also has a durable ignition system that improve its performance and the standard opening regulation that optimizes combustion increases heating effectiveness and the durability of the system.
Manufacturer:
https://www.partshnc.com/media/catalog/product/p/e/peerless_smart_gas_valve_1.png

Specifications

  • Type: Peerless Smart Gas
  • Ignition Type: Intermittent Hot Surface Pilot Ignition
  • Type of Fuel: Natural Gas
  • Regulation Type: Standard Opening
  • Connection Size: 1/2" NPT
  • Temperature Range: -40°F to 175°F
  • Operating Frequency: 50 Hz, 60 Hz
Write Your Own Review
You're reviewing:Resideo SV9501M2700/B Peerless Smart Gas Valve
Your Rating
Customer Questions
What maintenance is required for the Resideo SV9501M2700/B Smart Gas Valve?

Regularly inspect the gas valve for leaks, corrosion, or debris buildup. Ensure electrical connections are secure and the valve operates smoothly. Test the system periodically for proper response, and always shut off the gas supply and power before servicing for safety.

What are common issues with the Resideo SV9501M2700/B Smart Gas Valve?

  • Failure to open or close properly.
  • Gas leaks at connection points.
  • Erratic or inconsistent operation signals.
  • Loose or corroded wiring connections affecting performance.

Installation Steps

Step1: Turn off gas and electrical power to the appliance before starting.

Step2: Depressurize the gas line and disconnect existing gas valve fittings.

Step3: Remove old valve and install the new gas valve with correct orientation.

Step4: Tighten all gas fittings and reconnect electrical harness per wiring diagram.

Step5: Restore gas pressure and perform a leak test with soapy water or approved method.

Step6: Restore power, start the appliance, and verify proper gas flow and operation.