Facebook Pixel

Resideo RA889A1001 Switching Relay 120V SPDT 24V SPST

Special Price $91.32 Regular Price $105.02
In stock
SKU
RA889A1001
The Resideo RA889A1001 is a switching relay that can be used in different functions to control HVAC equipment. It operates on a 120V power supply and has switch action of SPDT 24V SPST; it is ideal for many heating and cooling systems such as boilers, air conditioners, and zone control units. This relay makes it possible for low-voltage thermostats to control high-voltage devices hence enhancing system reliability and energy utilization. This is ideal for applications where accurate switching is needed and has the bonus of reducing energy consumption, as well as increasing the duration of HVAC equipment through better control. It runs at a frequency of 60 Hz and is thus an essential and steady device.
https://www.partshnc.com/media/catalog/product/r/a/ra889a1001.jpg

Specifications

  • Type: Switching Relay
  • Voltage: 24V
  • Frequency: 60 Hz
  • Switch Action: 2 SPST
  • Length: 3.5"
  • Width: 4.44"
  • Height: 6.25"

Product Overview:
Switches electrical circuits within heating equipment to coordinate control operation between connected components. The Resideo RA889A1001 Switching Relay is an OEM electrical control component rated for 120V and 24V applications. Its switching function supports electrical control coordination in heating systems designed for the corresponding voltage requirements.

Switching Control:
The relay uses an SPDT switching arrangement together with a PowerPile-rated low-voltage SPST relay to provide switching across corresponding control and equipment circuits. The switching contacts change state according to the applicable control input, allowing the relay to coordinate connected line- and low-voltage circuits. A push-to-test button and troubleshooting LED are incorporated into the assembly for service and operational checking.

Transformer & Circuit Protection:
The integrated transformer converts the 120 Vac primary supply to a 24 Vac secondary supply for the applicable low-voltage circuit. The transformer is rated at 12 VA maximum, with 9 VA available for external loads. A replaceable 1A automotive fuse protects the secondary circuit within the relay assembly.

Replacement Guidelines:
Replace the Resideo RA889A1001 Switching relay when switching operation becomes unreliable, the relay no longer responds to the applicable control signal, or the transformer and protection circuit no longer provide the required output. Before selecting a replacement, compare the existing relay with the equipment documentation and verify the voltage requirements, switching configuration, contact ratings, thermostat requirements, and wiring arrangement.

Common Failure Symptoms:

  • Relay fails to switch connected equipment.
  • Push-to-test operation does not produce the expected response.
  • 24 Vac output is unavailable.
  • Relay operation becomes intermittent.
  • Fuse repeatedly opens or electrical components show visible damage.

Equipment Compatibility:
The Resideo RA889A1001 is intended for corresponding hydronic heating applications requiring intermediate switching between line- and low-voltage devices. Resideo specifies the relay for use with corresponding electromechanical and electronic 2- or 3-wire thermostats. Compare the existing equipment control arrangement and relay requirements with the specifications before selecting a replacement.

Technical Specifications:
Brand: Resideo
Part Number: RA889A1001
Product Type: Switching Relay
Input Voltage: 120V
Output Voltage: 24V

Write Your Own Review
You're reviewing:Resideo RA889A1001 Switching Relay 120V SPDT 24V SPST
Your Rating
Customer Questions
What is the Resideo RA889A1001 switching relay used for?

The RA889A1001 combines switching functions and an integral transformer for applicable hydronic heating control arrangements.

What should I verify before selecting the RA889A1001 relay?

Check the required relay model, thermostat wiring configuration, connected control requirements, and specified 120 Vac input and 24 Vac secondary against the equipment documentation.

Which thermostats are supported by the RA889A1001?

The relay is specified for applicable electromechanical and electronic 2-wire or 3-wire thermostats used in hydronic heating control systems. Confirm the thermostat requirements before installation.

What problems may indicate that a heating control relay needs replacement?

A connected heating circuit that fails to respond as intended may indicate a relay, transformer, wiring, or thermostat issue requiring diagnosis.

What maintenance is appropriate for a hydronic heating control relay?

During scheduled system servicing, have a qualified technician check the relay enclosure, wiring, terminals, and electrical connections for visible damage, looseness, or overheating.