Facebook Pixel

Resideo R841C1169 SPST Electric Heater Relay 208-240V

Special Price $131.58 Regular Price $151.32
In stock
SKU
R841C1169
The Resideo R841C1169 SPST Electric Heater Relay regulates the high voltage electric heaters in HVAC systems. This relay uses a coil voltage of 208/240V AC at 50/60 Hz to provide a reliable switch for heating control. It has also safety features that conform with the UL and CSA standards. This relay is suitable for home or low-rise commercial use and can handle an ambient temperature range of -20°F to 150°F which is suitable for most conditions. The lead wire connection type is easy to install and offers a practical way of managing electric heating systems.
https://www.partshnc.com/media/catalog/product/r/8/r841c1169.png

Specifications

  • Type: Relay
  • Approvals and Standards: UL Component Recognized: File No.E47434, Guide No. XAPX, CSA Certified
  • Coil Rating Voltage: 208 V AC, 240 V AC
  • Coil Connection Type: Leadwire
  • Number of Poles: 1
  • Frequency: 50/60 Hz
  • Switch Action: SPST
  • Temperature Range: -20°F to 150°F
  • Dimensions (LxWxH): 1.5"x2.81"x3.87"

Product Overview:
witches electrical power to an electric heating system through a single-pole, single-throw (SPST) relay configuration. The Resideo R841C1169 SPST Electric Heater Relay is an OEM electrical control component rated for 208–240V applications. Its relay function supports switching control within an electric heating system designed for the specified voltage range.

Heater Load Switching:
At the relay-contact level, heater load switching governs the electrical state presented to the designated heating circuit. The contact arrangement determines the circuit's switching condition when the relay receives the applicable control input. This function is limited to the relay's direct electrical interaction with the heater circuit, including contact-state changes and circuit continuity, without discussing the relay's broader role in heating-system sequencing or coordination.

Electric Heat Coordination:
During a heating demand cycle, electric heat coordination defines how the relay functions as an intermediary within the equipment's control logic. Its role is to associate the designated heating function with the control sequence established by other system components and to support the required stage of heat operation. This function addresses control-system relationships and heating-stage participation without describing relay contacts, circuit continuity, or load switching.

Replacement Guidelines:
Replace the Resideo R841C1169 SPST Electric Heater Relay 208-240V when the existing relay has deteriorated, has been removed during service, or no longer provides adequate electrical switching. Renew the relay during applicable maintenance or component replacement to restore the required switching function and support proper electric heater control.

Common Failure Symptoms:

  • Heater fails to energize when heat is requested.
  • Relay switching becomes intermittent between heating cycles.
  • Electrical contacts fail to close when activation is required.
  • Heating remains energized after the control demand ends.
  • Heater response becomes irregular across operating cycles.

Equipment Compatibility:
The Resideo R841C1169 SPST Electric Heater Relay 208-240V is intended for electric heating equipment requiring an SPST relay for controlled heater switching. Its application depends on the associated heating circuit and electrical control arrangement. Verify the R841C1169 equipment model and manufacturer's parts documentation before ordering.

Technical Specifications:
Brand: Resideo
Part Number: R841C1169
Product Type: Electric Heater Relay
Connection Type: SPST
Voltage: 208-240V
Contact Configuration: SPST

Write Your Own Review
You're reviewing:Resideo R841C1169 SPST Electric Heater Relay 208-240V
Your Rating
Customer Questions
Which electric heating applications is the R841C1169 intended to control?

The R841C1169 provides relay-based electrical control for a designated electric heater circuit. Confirm the heating equipment's requirements before selecting this relay.

What should I compare before purchasing a replacement for the R841C1169?

Match the part number, contact configuration, electrical ratings, wiring arrangement, and heater requirements against the existing relay and equipment documentation.

Why does the SPST contact arrangement matter when choosing a heater relay?

SPST means single-pole, single-throw, describing a relay contact arrangement that switches one circuit through a single switching path. The configuration must suit the intended heater circuit.

Can the R841C1169 be used in a 208–240V heating application?

The 208–240V designation identifies the specified voltage range associated with the relay's application. Confirm the relevant electrical ratings and circuit requirements before installation.

What signs may indicate that an electric heater relay needs servicing?

A heater that fails to switch as expected or operates intermittently may have a relay, wiring, or control-circuit fault. Have a qualified technician inspect the system and verify relay operation before replacing components.