Resideo R8285B1038 Fan Center W/DPDT Switching Action 40 VA 120V

Special Price $92.56 Regular Price $106.44
Out of stock
SKU
R8285B1038
The Resideo R8285B1038 Fan Center with DPDT Switching Action is an essential part of HVAC systems, which is used for the control of the fan and other electrical processes. Various models of this fan center are available in 120 volts AC and 60 Hz capacity offering greater reliability in a broad range of heating and cooling applications. It has Double Pole Double Throw switch action and two poles which give the user flexibility in controlling the fan and system. The device also has a power rating of 40VA and is therefore suitable for use in low voltage circuits, HVACs in particular.
Manufacturer:
https://www.partshnc.com/media/catalog/product/r/8/r8285b1038_resideo_partshnc.jpg

Specifications

  • Frequency: 60 Hz
  • Switch Action: DPDT
  • Number of Poles: 2
  • Input Voltage: 24 VAC
  • Height: 4.19"
  • Width: 4.5"
  • Type: Heat Sequencer
  • On Timing Delay: 1–110 Seconds
  • Off Timing Delay: 1–110 Seconds
  • Contact Rating: 25A Resistive, 14A Inductive at 120 VAC
  • Electrical Connections: Solder or Screw Type 1/4" Quick Connect

Product Overview:
Coordinates electrical switching for fan motors and auxiliary circuits in HVAC equipment. The Resideo R8285B1038 3/4HP DPDT Fan Center With Switching 40VA 120 VAC/26.5 VAC SEC is an OEM fan-control component featuring DPDT switching, a 3/4 HP motor rating, a 40 VA rating, 120 VAC primary voltage, and 26.5 VAC secondary voltage. Its switching arrangement supports control of connected fan and auxiliary circuits.

Fan Control:
Controls the electrical connection of the associated fan motor by changing the state of the dedicated fan switching contacts. The switching action determines whether the fan circuit receives the required electrical connection during the applicable equipment operating condition. This function focuses specifically on establishing or interrupting the fan motor circuit and does not address the operation of separate auxiliary loads or their associated control paths.

Auxiliary Control:
Provides switched electrical connections for secondary equipment functions associated with the HVAC system. The auxiliary contacts can be used to control an additional electrical load independently from the primary fan-motor circuit. This function focuses specifically on the relay's ability to provide a separate switching path for auxiliary equipment and does not describe the electrical control of the primary fan motor.

Replacement Guidelines:
Replace the Resideo R8285B1038 3/4HP DPDT Fan Center With Switching 40VA 120 VAC/26.5 VAC SEC when the existing fan center has deteriorated, has been removed during service, or no longer provides adequate electrical switching. Renew the fan center during applicable maintenance or component replacement to restore the required switching function and support proper fan control.

Common Failure Symptoms:

  • Fan control response becomes intermittent or delayed.
  • DPDT contacts fail to switch between positions.
  • Connected fan circuits remain in an unchanged state.
  • Switching action varies between successive control cycles.
  • Electrical contacts fail to transfer as commanded.

Equipment Compatibility:
The Resideo R8285B1038 3/4HP Fan Center With Switching 120 VAC/26.5 VAC SEC is intended for corresponding equipment requiring a DPDT fan center with a 40VA switching configuration. Its application depends on the associated equipment and fan-control arrangement. Verify the R8285B1038 equipment model and manufacturer’s parts documentation before ordering.

Technical Specifications:
Brand: Resideo
Product Type: Fan Center
Motor Rating: 3/4HP
Contact Configuration: DPDT
Switching: With Switching
VA Rating: 40VA
Voltage: 120 VAC
Secondary Voltage: 26.5 VAC

Write Your Own Review
You're reviewing:Resideo R8285B1038 Fan Center W/DPDT Switching Action 40 VA 120V
Your Rating
Customer Questions
What is the Resideo R8285B1038 fan center used for?

It uses low-voltage control signals and switching contacts to manage fan motor operation and an associated auxiliary circuit.

How does the fan center separate control and load circuits?

The control circuit operates the switching mechanism, while the contacts manage the electrical paths serving the connected loads.

What does the DPDT configuration provide?

Double-pole, double-throw switching provides two poles, each capable of switching between two contact positions.

What happens when the fan contacts change state?

The contacts establish or interrupt the designated electrical path, changing power delivery to the connected fan circuit.

How should the R8285B1038 be inspected and maintained?

Check for damaged wiring, loose connections, overheating, or contact deterioration. A qualified technician should test switching operation and electrical connections.