Facebook Pixel

Resideo R8184M1051 Relay Oil Burner Control 45 Sec

Special Price $246.72 Regular Price $273.86
In stock
SKU
R8184M1051
The Resideo R8184M1051 is a 45-second burner protection relay for use in oil-fired heating systems. It controls the ignition and valve so that there is no danger of overheating or damage to the oil burner. This relay is designed in an intermittent ignition style which is ideal for controlling the burner cycle. The device is small, 4.75" long, 4.37" tall, and 4.13" wide, and gray, with measurements. The burner has a 45-second valve on delay timing, which allows the burner to stabilize before the valve opens, ensuring reliable ignition and reducing the chance of misfires. It is small enough to be installed in a variety of HVAC systems, such as furnaces and boilers.
Manufacturer:
https://www.partshnc.com/media/catalog/product/r/8/r8184m1051_1.jpg

Specifications

  • Ignition Type: Intermittent
  • Color: Gray
  • Product Length: 4.75"
  • Valve On Delay Timing: 45 sec
  • Product Height: 4.37"
  • Product Width: 4.13"
  • Type: Oil Burner Control
  • Safety Timing: 45 Seconds
  • Mounting Type: Standard 4" × 4" Junction Box
  • Full Load Rating: 7.4 A/120 VAC, 3.7 A/240 VAC
  • Locked Rotor Rating: 44.4 A/120 VAC, 22.2 A/240 VAC
  • Includes: 40 VA Transformer

Product Overview:
Controls the ignition and operating sequence of intermittent-ignition oil burner systems while monitoring burner flame status. The Resideo R8184M1051 Relay Oil Burner Control 45-Sec is an OEM electronic control component that coordinates the ignition transformer, oil valve, and burner operation according to the control sequence. Its flame-sensing circuit supports burner safety control, and its 45-second safety timing defines the specified timing characteristic.

Flame Sensing:
Monitors the presence of the burner flame through the associated detection circuit during oil burner operation. The control receives a signal from the flame detector and evaluates that input as part of its safety response. This function focuses on identifying whether combustion has been established at the burner, allowing the control to recognize the detected flame state and provide the corresponding electrical response within the burner-control arrangement.

Ignition Control:
Manages the electrical outputs associated with establishing burner ignition in an oil-fired system. The control coordinates the ignition transformer, oil burner, and oil valve according to the required electrical sequence. This function organizes the timing and interaction of the connected ignition components following a call for heat, providing the electrical commands needed to initiate and sustain the designated burner-start sequence.

Replacement Guidelines:
Replace the Resideo R8184M1051 Relay Oil Burner Control 45-Sec when the existing oil burner control has deteriorated, has been removed during service, or no longer provides adequate burner-control function. Renew the control during applicable maintenance or component replacement to restore the required burner-control function and support proper oil burner operation.

Common Failure Symptoms:

  • Irregular flame sensing response during ignition cycles.
  • Unexpected safety shutdown during burner cycles.
  • Inconsistent ignition sequence during burner startup.
  • Physical deterioration affecting the control response.
  • Irregular switching response at elevated temperatures.

Equipment Compatibility:
The Resideo R8184M1051 Relay Oil Burner Control 45-Sec is designed for corresponding intermittent-ignition oil burner systems using the corresponding oil primary control arrangement. Application may vary by burner configuration, control circuit, flame-detector arrangement, and equipment design. Always verify the R8184M1051 equipment model, control arrangement, and applicable parts documentation before selecting this control.

Technical Specifications:
Brand: Resideo
Part Number: R8184M1051
Product Type: Relay Oil Burner Control
Safety Timing: 45-Sec

Write Your Own Review
You're reviewing:Resideo R8184M1051 Relay Oil Burner Control 45 Sec
Your Rating
Customer Questions
What is the Resideo R8184M1051 oil primary control used for?

It coordinates the electrical functions involved in oil burner ignition and flame monitoring.

How does flame detection support burner operation?

It signals whether the expected flame condition is detected, allowing the control to respond accordingly.

What happens if the expected flame is not detected?

The safety sequence responds when the required combustion condition is not confirmed during burner operation.

What signs may indicate a faulty oil primary control?

Failed burner startup, interrupted operation, or inconsistent flame monitoring may indicate a control problem requiring inspection.

How should the R8184M1051 primary control be inspected?

Check for visible damage and deteriorated electrical connections. Have a qualified technician test the control and safety functions according to the manufacturer's instructions.