Facebook Pixel

Resideo Q347A1012 Direct Spark Igniter 90-1/2° Angle Rod Style D Bracket

Special Price $66.70 Regular Price $76.70
In stock
SKU
Q347A1012
The Resideo Q347A1012 Direct Spark Igniter is an essential part that creates a spark to the primary burner flame in gas-fired HVAC systems. It has a 90° right angle mounting bracket with spark rod length of 2.03 inches. The igniter of this heating system has a high temperature tolerance of up to 1250°F and is built to withstand the conditions within a heating system. This module is designed for models S87C, S89E, S89F, and Q354A, and it provides consistent ignition in furnaces, boilers, and water heaters as well as other gas-fired appliances. The direct spark igniter is used to ignite the burner effectively and consistently enhancing the system efficiency and energy economy.
https://www.partshnc.com/media/catalog/product/q/3/q347a1012.jpg

Specifications

  • Application: Direct Main Burner Ignition
  • Bracket Style: D
  • Spark Rod Length: 2.03"
  • Temperature Rating: 1250°F
  • For Use With: S87C, S87D, S87K, S89E, S89F, Q354A
  • Type: Spark Igniter
  • Rod Length: 2-1/32"
  • Rod Angle: 90-1/2°

Product Overview:
Generates the electrical spark required to ignite the main burner in gas-fired heating equipment. The Resideo Q347A1012 Direct Spark Igniter With Mounting Bracket 90° Right Angle Style-D is an OEM ignition component featuring a Kanthal electrode, ceramic insulator, mounting bracket, and ground strap. Its 90-degree right-angle rod configuration establishes the electrode’s position within the direct-spark ignition assembly.

Spark Ignition:
Generates the electrical spark required to initiate direct ignition at the main burner. The electrode and ground arrangement establish the spark path at the burner location, allowing the associated ignition control to deliver the electrical discharge needed for ignition. This process provides the ignition event required for the main burner to establish a flame during the equipment’s ignition sequence.

Mounting Position:
Uses a Style D mounting arrangement with a 90-degree rod orientation to position the igniter electrode within the burner assembly. The bracket establishes the physical relationship between the igniter and its mounting location, while the right-angle rod places the electrode at the designated position within the ignition assembly. This configuration defines how the igniter is physically positioned relative to the burner.

Replacement Guidelines:
The Resideo Q347A1012 Direct Spark Igniter With Mounting Bracket may require replacement if the electrode, ceramic insulator, or ground strap is damaged, or if the igniter no longer produces the spark needed to ignite the main burner. When replacing this component, preserve the required Style D mounting bracket and 90-degree right-angle rod orientation, as these features define its physical configuration.

Common Failure Symptoms:

  • Misaligned igniter bracket positioning at the mount
  • Loose support around the igniter mounting area
  • Deformed bracket affecting igniter alignment
  • Cracks or damage across the bracket structure
  • Improper fit at the designated mounting location

Equipment Compatibility:
The Resideo Q347A1012 Direct Spark Igniter Mounting Bracket is designed for corresponding direct-spark ignition systems that specify this igniter arrangement. Always verify the Q347A1012 equipment model number and manufacturer's parts documentation before purchasing.

Technical Specifications:
Brand: Resideo
Part Number: Q347A1012
Product Type: Direct Spark Igniter
Mounting Bracket: D-Style
Rod Angle: 90° Right Angle

Write Your Own Review
You're reviewing:Resideo Q347A1012 Direct Spark Igniter 90-1/2° Angle Rod Style D Bracket
Your Rating
Customer Questions
What is the Resideo Q347A1012 direct spark igniter used for?

It produces the electrical spark needed to initiate ignition in applicable gas-fired equipment.

How does the ceramic insulator support igniter operation?

It electrically separates the electrode from the surrounding assembly and holds it in position.

What is the function of the igniter’s ground strap?

It provides the electrical path that works with the electrode to establish the ignition spark gap.

What signs may indicate a faulty direct spark igniter?

Failure to produce a spark, visible damage, or deterioration of the electrode or insulator may indicate a problem.

How should a direct spark igniter be inspected?

Check for cracks, electrode damage, and deterioration. Follow the equipment manufacturer's service instructions and have ignition-system testing performed by a qualified technician.