The Resideo Q3400A1032 High Temperature Igniter Flame Rod Assembly is a component that is utilized with hot surface pilot burners in heating devices. This assembly is an igniter and flame rod, which ensures that ignition of the heating process and sensing of the flame in gas-fired heating are well achieved. It is compatible with systems that utilize a hot surface ignition process and has a heating output of 1000 BTU, making it ideal for many residential and commercial heating and cooling purposes. It has a 30" ignition wire, and that makes it possible to fit it in several positions as required.
https://www.partshnc.com/media/catalog/product/q/3/q3400a1032_resideo_partshnc.png

Specifications

  • Application: Flame Rod Assembly
  • Compatible With: Hot Surface Pilot Burners
  • Dimensions: Ignition Wire Length 30"
  • Pilot Btuh: 1000 Btuh heating output
Manufacturer Name: Resideo
Product Number: Q3400A1032
OEM Part Number: Q3400A1032
Product Description: Hsi Pilotburnr,Q3450-3620-3480
Weight:0.21lbs/95.25g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Resideo Q3400A1032 High Temperature Igniter & Flame Rod Assembly
Your Rating
Customer Questions
What maintenance is required for the Resideo Q3400A1032 Igniter & Flame Rod Assembly?

Regularly inspect the igniter and flame rod for soot, dirt, or corrosion that can affect performance. Clean gently with appropriate tools to avoid damage. Proper maintenance ensures reliable ignition and safe operation. Always disconnect power and fuel supply before servicing.

What are common issues with the Resideo Q3400A1032 Igniter & Flame Rod Assembly?

  • Igniter failing to spark or ignite.
  • Flame rod not sensing flame properly.
  • Soot buildup causing inconsistent detection.
  • Corrosion or wear on ignition components.
  • Intermittent ignition cycles or misfires.

Installation Steps

Step 1: Turn off power and gas supply to the heating system.

Step 2: Access the burner assembly and locate the igniter/flame rod.

Step 3: Disconnect wiring and remove mounting screws carefully.

Step 4: Install the new assembly in the same position and secure it.

Step 5: Reconnect wiring firmly to the correct terminals.

Step 6: Restore gas and power, then test ignitio avoid touching hot surfaces.