The Rheem-Ruud PD619094 Thermal Expansion Valve Kit is one of the most essentialkits toward the enhancement of functionalities among HVAC systems. The amount of refrigerant coming into the evaporator is controlled so that proper heat exchange may be achieved and efficiency improved in a system. A TXV always ensures that the correct at any given time. This prevents under-feeding and overfeeding, which causes poor heat or cooling; it damages the system. Being part of many HVAC units, such as a Kit, it is a crucialcomponent in the stability of the system and its durability. Another benefit of the TXV kit is that it governs against the demand of the load, therefore improving energy use and translating to a reduction in energy cost.
Manufacturer:
https://www.partshnc.com/media/catalog/product/p/d/pd619094.jpg

Specifications

  • Weight: 1.08 lbs
  • Type: Thermal Expansion Valve Kit
Manufacturer Name: Rheem-Ruud
Product Number: PD619094
OEM Part Number: PD619094
Product Description: Txv Kit
Weight:1.08lbs/489.88g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Rheem-Ruud PD619094 Thermal Expansion Valve(TXV) Kit
Your Rating
Customer Questions
What maintenance is required for the Rheem-Ruud PD619094 Thermal Expansion Valve Kit?

Inspect the valve regularly for refrigerant leaks and ensure fittings remain tight. Clean debris around connections and check for corrosion. Proper maintenance ensures efficient refrigerant flow and prevents system pressure imbalance or cooling performance issues.

What are common issues with the Rheem-Ruud PD619094 Thermal Expansion Valve Kit?

  • Refrigerant leakage at valve seals or joints.
  • Inconsistent cooling due to improper metering.
  • Valve sticking or clogging from debris buildup.
  • Erratic pressure readings in systems.
  • Reduced efficiency from restricted refrigerant flow.

Installation Steps

Step 1: Turn off HVAC power and recover refrigerant safely.

Step 2: Remove access panel and extract old thermal expansion valve.

Step 3: Clean lines and install new thermal expansion valve in correct orientation, braze connections.

Step 4: Secure sensing bulb properly insulated and fastened to suction line.

Step 5: Evacuate system, perform leak test, and recharge refrigerant.

Step 6: Restore power and verify system operation.