Facebook Pixel

Rheem-Ruud PD425145 Pressure Switch Assembly

Special Price $20.55 Regular Price $26.72
In stock
SKU
PD425145
The Rheem-Ruud PD425145 Pressure Switch Assembly is an essential component of the pressure regulating equipment of HVAC appliances. This pressure switch ensures that the pressure of the system is correct, and thus the system does not pose any threat or is not a waste of resources. This switch, with the pressure rating of 0. 7, controls the pressure level and turns on or off the components that help to maintain the system in the most suitable state.
https://www.partshnc.com/media/catalog/product/p/d/pd425145.jpg

Specifications

  • Weight: 0.14 lbs
  • Type: Pressure Switch
  • Pressure Rating: 0.7"
Manufacturer Name: Rheem-Ruud
Product Number: PD425145
OEM Part Number: PD425145
Product Description: Pressure Switch Assy
Weight:0.14lbs/63.5g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Rheem-Ruud PD425145 Pressure Switch Assembly
Your Rating
Customer Questions
What maintenance is required for the Rheem-Ruud PD425145 Pressure Switch Assembly?

Inspect wiring connections and tubing regularly for looseness, corrosion, or cracks. Clean sensing ports to prevent dust or moisture buildup affecting pressure readings. Verify switch operation during routine system checks and replace damaged components promptly.

What are common issues with the Rheem-Ruud PD425145 Pressure Switch Assembly?

  • Faulty pressure sensing causing incorrect switch activation.
  • Cracked or blocked tubing restricting airflow sensing.
  • Electrical connection failure or loose wiring signals.
  • False pressure readings leading to system lockout.

Installation Steps

Step 1: Turn off electrical power and gas supply to the HVAC system; check unit is fully isolated.

Step 2: Remove access panel and locate existing pressure switch and tubing.

Step 3: Label and disconnect low-voltage wiring terminals carefully.

Step 4: Detach pressure sensing hoses from the old switch.

Step 5: Remove mounting screws and extract old switch assembly.

Step 6: Install new switch in same orientation and secure firmly.

Step 7: Reconnect tubing and wiring exactly as labeled.

Step 8: Restore power and gas, then test ignition sequence and check proper pressure response and safety cutoff operation.