Facebook Pixel

Williams Comfort Products P322660 10 Inch Wc Lp 1/2 Inch Gas Valve

Special Price $299.45 Regular Price $332.39
In stock
SKU
P322660

Williams Comfort Products' P322660 is a specialty 1/2-inch gas valve designed for low-pressure HVAC systems using liquid propane. This propane furnace is perfect for standard household furnaces, with a pressure tolerance of 10 inches of water column. This valve efficiently controls the gas flow to the burner, guaranteeing that the furnace's heat output is optimally regulated. Through the process of transforming incoming gas pressure into a steady, regulated flow, it facilitates the system's safe and effective combustion. A faulty P322660 valve is often used in the Williams Comfort Products WCM-14 to WCM-21 furnace models. Replacing this valve can solve problems such as uneven heating, problems with the pilot light, or general furnace faults. Using this valve has a number of benefits, such as improved system dependability, accurate temperature control, and increased fuel efficiency.

https://www.partshnc.com/media/catalog/product/p/3/p322660.jpg

Product Overview:
Serves as a fuel-control component within heating equipment, regulating liquid propane through the gas train. The Williams Comfort Products P322660 1/2" LP Gas Valve 10" WC is designed for LP fuel applications with a 1/2" connection size and 10" WC pressure specification. The valve responds to heating control signals to regulate fuel passage toward the burner circuit.

Fuel Passage and Pressure Control:
The gas valve regulates liquid propane flow in response to the heating system's control signal. It manages fuel passage from the incoming supply toward the burner circuit, providing a controlled pathway during active heating demand.

Heating Demand and Fuel Shutoff:
Within the appliance operating sequence, the valve functions as an inline fuel-control component connected to the heating system controls. It manages fuel passage during operation and stops the flow when the heating demand ends, supporting the required shutoff action.

Replacement Guidelines:
Consider replacing the Williams Comfort Products P322660 1/2" LP Gas Valve 10" WC when fuel control becomes inconsistent, the valve fails to respond correctly to operating signals, or physical damage or gas leakage is present.

Common Failure Symptoms:

  • Main burner fails to ignite during a call for heat.
  • Fuel flow continues after the heating demand ends.
  • Gas flow becomes intermittent during operation.
  • Gas odor is present around the equipment.
  • Burner operation becomes inconsistent due to disrupted fuel delivery.

Equipment Compatibility:
The Williams Comfort Products P322660 1/2" LP Gas Valve 10" WC is specified for heating equipment requiring LP fuel, a 1/2" connection size, and a 10" WC pressure specification. Verify the unit model, fuel requirements, and pressure specifications against the applicable appliance service documentation before selecting the valve.

Technical Specifications:
Brand: Williams Comfort Products
Part Number: P322660
Product Type: Gas Valve
Fuel Type: Liquid Propane (LP)
Connection Size: 1/2"
Pressure Specification: 10" WC

Write Your Own Review
You're reviewing:Williams Comfort Products P322660 10 Inch Wc Lp 1/2 Inch Gas Valve
Your Rating
Customer Questions
What maintenance is required for the Williams Comfort Products P322660 Gas Valve?

Regularly inspect the valve for leaks, corrosion, or physical damage. Ensure connections are secure and free of debris. Test operation periodically to confirm proper flow. Always follow gas safety guidelines when handling or servicing the valve.

What are common issues with the Williams Comfort Products P322660 Gas Valve?

  • Gas leakage or odor.
  • Valve sticking or failing to open/close.
  • Pressure inconsistencies.
  • Corrosion or buildup affecting operation.

What does the Williams Comfort Products P322660 gas valve do in a heating system?

The Williams Comfort Products P322660 gas valve manages fuel flow within heating equipment by regulating fuel passage toward the burner circuit.

How does the P322660 LP gas valve respond to the heating system controls?

The valve responds to the heating control signal to regulate fuel passage according to the equipment's heating demand.

Where does the P322660 gas valve operate within the heating equipment?

The gas valve operates within the gas train between the incoming fuel supply and the burner assembly.

What should be checked when maintaining a gas valve such as the P322660?

The gas valve should be inspected as part of appropriate heating-equipment service to help identify conditions that could affect fuel control or the valve's shutoff function. Follow the equipment manufacturer's service requirements for specific inspection or servicing procedures.

What happens when the heating control signal is removed from the P322660 gas valve?

The valve stops fuel passage toward the burner, providing the required shutoff action within the operating sequence.

Installation Steps

Step1: Turn off the gas supply and disconnect power for safety.

Step2: Remove the old gas valve by loosening all fittings and connections.

Step3: Inspect pipe threads and clean as needed.

Step4: Install the new gas valve in the correct orientation.

Step5: Tighten all connections securely without overtightening.

Step6: Restore gas supply and check for leaks.

Step7: Reconnect power and test the system for proper gas flow and operation.