Honeywell Sensing and Control OP-AR62 Enclosed Limit Switch W/Side Rotary 15A 480V

Special Price $525.75 Regular Price $583.58
In stock
SKU
OP-AR62
The Honeywell Sensing and Control OP-AR62 Enclosed Switch is a durable, high performance limit switch for industrial and HVAC systems. It has 480V rated working voltage and maximum current 15A, with a Side Rotary actuator, and is intended to control and monitor mechanical movements. It is widely used in air handlers, dampers and ventilation systems, to provide precise position detection and reliable operation in enclosed switches. That is durable, which means that it is quite robust, particularly better as needing less maintenance in harsh environments. Benefits include increased safety, precise control, and long lasting performance, and it is a reliable solution for automation and HVAC systems that demand the ability to switch with accuracy.
https://www.partshnc.com/media/catalog/product/o/p/op-ar62.jpg

Specifications

  • Type: Enclosed Switch
  • Series: Side Rotary
  • Voltage: 480V
  • Current: 15A
Manufacturer Name: Honeywell Sensing and Control
Product Number: OP-AR62
OEM Part Number: OP-AR62
Product Description: Enclosedswitch 15A 480V Sidero
Weight:1.28lbs/580.6g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Honeywell Sensing and Control OP-AR62 Enclosed Limit Switch W/Side Rotary 15A 480V
Your Rating
Customer Questions
What maintenance is required for the Honeywell Sensing and Control OP-AR62 Limit Switch?

Regularly check the switch for dirt, dust, or debris that could obstruct movement. Inspect the rotary mechanism and electrical connections for wear or looseness. Lubricate moving parts lightly if needed and follow proper safety precautions when handling live circuits.

What are common issues with the Honeywell Sensing and Control OP-AR62 Limit Switch?

  • Sticking or jammed rotary mechanism.
  • Erratic electrical contact or signal failure.
  • Corrosion or debris buildup.
  • Loose or damaged wiring affecting operation.

Installation Steps

Step 1: Disconnect power and verify zero voltage before installation to ensure safety.

Step 2: Mount the new switch on rigid surface using proper hardware, align actuator with cam.

Step 3: Connect wiring to terminals per the control diagram, ensuring correct load rating.

Step 4: Adjust rotary actuator position for proper trip points.

Step 5: Restore power, test switch operation, verify accurate limit response.