Facebook Pixel

Nidec-Embraco NT6220GKV1 3/4HP Compressor R404A, 115V/1PH

Special Price $757.93 Regular Price $841.30
In stock
SKU
NT6220GKV1
The Nidec-Embraco NT6220GKV1 Hermetic Compressor is intended for refrigeration applications employing R404A refrigerant. This air compressor has a capacity of 3/4 horsepower, using a 115 V single-phase supply power source suitable for general commercial refrigeration sales applications such as display cases, walk-in coolers and beverage vending machines among others. During compression, the pressure and temperature of the gas increase, and it becomes capable of moving throughout the HVAC system, altering temperatures and carrying heat. This compressor is perfect for companies who are seeking to improve their refrigeration equipment and at the same time save on costs and energy.
https://www.partshnc.com/media/catalog/product/n/t/nt6220gkv1.jpg

Specifications

  • Size: 8.0"
  • Horsepower: 3/4 HP
  • Voltage: 115V
  • Frequency: 50Hz
  • Phase: 1
  • Weight: 39.47 Lbs
Manufacturer Name: Nidec-Embraco
Product Number: NT6220GKV1
OEM Part Number: NT6220GKV1
Product Description: 115V1ph R404a 3/4Hp Comp
Weight:39.47lbs/17903.28g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Nidec-Embraco NT6220GKV1 3/4HP Compressor R404A, 115V/1PH
Your Rating
Customer Questions
What maintenance is required for the Nidec-Embraco NT6220GKV1 Compressor?

Regularly inspect the compressor for dust, dirt, and oil leaks. Check electrical connections and ensure proper voltage supply. Monitor refrigerant levels and pressure to maintain efficiency. Clean surrounding components and follow safety precautions when handling high-voltage parts.

What are common issues with the Nidec-Embraco NT6220GKV1 Compressor?

  • Overheating or excessive noise.
  • Reduced cooling performance.
  • Electrical failures or blown fuses.
  • Refrigerant leaks or pressure inconsistencies.

Installation Steps

Step 1: Disconnect power and recover refrigerant safely.

Step 2: Remove old compressor and clean tubing connections.

Step 3: Mount new compressor on vibration mounts and secure.

Step 4: Braze suction and discharge lines carefully to avoid overheating components.

Step 5: Evacuate system, check for leaks, then charge refrigerant.

Step 6: Restore power and verify pressures and cooling performance.