Facebook Pixel

Cleveland Controls NS2-0220-00 SPDT Pressure Switch 1.25" WC

Special Price $62.92 Regular Price $72.36
In stock
SKU
NS2-0220-00
The Cleveland Controls NS2-0220-00 Pressure Switch of SPDT is meant to monitor and act upon fluctuating air pressure in HVAC systems. Maintaining a standard pressure of 1.25 inches of water column this switch functions as a pressure sensor in different processes. If the pressure in the system rises above 1.25 inches of water column, the switch inside changes the electrical circuit to cause a response. This response can include turning on alarms, operating fans, or changing the position of dampers in a bid to get the right system performance and efficiency.
https://www.partshnc.com/media/catalog/product/n/s/ns2-0220-00_1.jpg

Specifications

  • Type: Pressure Switch
  • Switch Type: SPDT
  • Pressure: 1.25" water column
Manufacturer Name: Cleveland Controls
Product Number: NS2-0220-00
OEM Part Number: NS2-0220-00
Product Description: 1.25"Wc Spdt Pressure Switch
Weight:0.2lbs/90.72g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Cleveland Controls NS2-0220-00 SPDT Pressure Switch 1.25" WC
Your Rating
Customer Questions
What maintenance is required for the Cleveland Controls NS2-0220-00 Pressure Switch?

Inspect pressure tubing and sensing ports regularly to prevent blockages or moisture buildup. Ensure electrical contacts are tight and free from corrosion. Periodically verify calibration for accurate switching. Always isolate power before servicing for safety.

What are common issues with the Cleveland Controls NS2-0220-00 Pressure Switch?

  • Pressure sensing port blockage causing incorrect switching.
  • Electrical contact wear leading to intermittent operation.
  • Calibration drift resulting in inaccurate pressure response.
  • False triggering due to vibration or airflow fluctuations.
  • Diaphragm stiffness affecting sensitivity.

Installation Steps

Step 1: Turn off power to HVAC system and verify zero voltage.

Step 2: Mount switch on the duct or line port using manufacturer orientation.

Step 3: Connect terminals according to wiring diagram, ensure secure, insulated connections.

Step 4: Set pressure range then slowly restore power and test operation with HVAC airflow.

Step 5: Check for leaks and confirm switch actuates correctly.