SKJ72QD
The NORITZ SKJ72QD Flame Lifting Detection W/Gasket is a safety sensing component used in gas-fired heating equipment to monitor combustion conditions in HVAC systems. Supplied with a gasket, this assembly provides a secure mounting point while maintain proper sealing around the detection area. It identifies abnormal flame movement and sends feedback to the units safety system for appropriate response. It is positioned near the combustion chamber, this component assists with safe operation, supports proper monitoring, and maintain proper operationality of water heating equipment.
Manufacturer:
https://www.partshnc.com/media/catalog/product/s/k/skj72qd.jpg
Write Your Own Review
You're reviewing:Noritz SKJ72QD Flame Lifting Detection
Your Rating
Customer Questions
What maintenance is required for the NORITZ SKJ72QD Flame Lifting Detection?

Inspect the detection component regularly for soot, dust, or residue that may interfere with accurate flame sensing. Clean it carefully to maintain proper operation. Ensure wiring connections are secure and undamaged. Always turn off power and gas supply before performing any maintenance.

What are common issues with the NORITZ SKJ72QD Flame Lifting Detection?

  • False flame lifting detection triggering shutdowns.
  • Sensor contamination causing inaccurate readings.
  • Loose or damaged wiring affecting signal transmission.
  • Failure to detect flame conditions properly.

Installation Steps

Step 1: Turn off the appliance and disconnect power and gas for safety.

Step 2: Locate the existing flame detection assembly and remove it carefully.

Step 3: Position the new flame lifting detection unit in proper orientation.

Step 4: Secure with mounting hardware and ensure gasket/seals are correctly placed.

Step 5: Reconnect wiring per manufacturer specs.

Step 6: Restore power and gas, then test the system to confirm correct flame detection.