Facebook Pixel

Nidec-Embraco NEK6212Z1 R134A 1/2Hp Compressor R134A -1PH/115V

Special Price $491.97 Regular Price $546.08
In stock
SKU
NEK6212Z1
Nidec-Embraco NEK6212Z1 R134A 1/2HP Compressor essential in refrigerator and its working standard is high. The compressor is a single-phase, 115V, 60 Hz, 1/2 HP unit with a built-in thermal protector and uses R134A refrigerant to facilitate cooling in HVAC and commercial refrigeration equipment. The compressor has conventional mounting. It is easy to install and can blend well with the existing equipment installation without much of a hassle. This makes it have long-term durability and optimum performance regardless of the operating conditions it endures. The existence of the compressor is to compress the R134A refrigerant gas and by passing through the system the gas picks up heat within the intended room or equipment and then cools.
https://www.partshnc.com/media/catalog/product/n/e/nek6212z1.jpg

Specifications

  • Weight: 25.05 lbs
  • Refrigerant: R134A
  • Horsepower: 1/2 HP
  • Voltage: 115 V
  • Phase: 1-Phase
  • Frequency: 60 Hz
  • Voltage: 115 V
  • Mounting Type: Standard
Manufacturer Name: Nidec-Embraco
Product Number: NEK6212Z1
OEM Part Number: NEK6212Z1
Product Description: 115V1ph R134a 1/2Hp Compressor
Weight:25.05lbs/11362.48g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Nidec-Embraco NEK6212Z1 R134A 1/2Hp Compressor R134A -1PH/115V
Your Rating
Customer Questions
What maintenance is required for the Nidec-Embraco NEK6212Z1 Compressor?

Inspect refrigerant charge regularly and ensure proper levels to maintain efficient cooling. Keep electrical terminals tight and clean to prevent faults. Clean condenser coils and ensure adequate airflow to avoid overheating.

What are common issues with the Nidec-Embraco NEK6212Z1 Compressor?

  • Failure to start due to faulty start relay or capacitor.
  • Overheating from restricted airflow or dirty condenser.
  • Low cooling performance from refrigerant leaks or inefficiency.
  • Unusual noise from internal wear or loose mounting.

Installation Steps

Step 1: Disconnect electrical power and recover refrigerant safely before removal.

Step 2: Remove old compressor, noting suction/discharge line positions and wiring connections.

Step 3: Install new compressor on mounting base, ensuring level placement and secure fastening.

Step 4: Braze suction and discharge lines using proper nitrogen purge to avoid contamination.

Step 5: Reconnect electrical terminals and check correct voltage.

Step 6: Evacuate system to deep vacuum, and check for leaks.

Step 7: Start unit and monitor pressure, sound, and temperature for stable operation.