Facebook Pixel

Nidec-Embraco NEK6212Z1 1/2HP Hermetic Reciprocating Compressor R134a 115V 1-Phase

Special Price $491.97 Regular Price $546.08
In stock
SKU
NEK6212Z1
Nidec-Embraco NEK6212Z1 R134A 1/2HP Compressor essential in refrigerator and its working standard is high. The compressor is a single-phase, 115V, 60 Hz, 1/2 HP unit with a built-in thermal protector and uses R134A refrigerant to facilitate cooling in HVAC and commercial refrigeration equipment. The compressor has conventional mounting. It is easy to install and can blend well with the existing equipment installation without much of a hassle. This makes it have long-term durability and optimum performance regardless of the operating conditions it endures. The existence of the compressor is to compress the R134A refrigerant gas and by passing through the system the gas picks up heat within the intended room or equipment and then cools.
https://www.partshnc.com/media/catalog/product/n/e/nek6212z1.jpg

Specifications

  • Weight: 25.05 lbs
  • Refrigerant: R134A
  • Horsepower: 1/2 HP
  • Voltage: 115 V
  • Phase: 1-Phase
  • Frequency: 60 Hz
  • Voltage: 115 V
  • Mounting Type: Standard

Refrigeration appliances use compressors to circulate refrigerant and maintain the cooling conditions required for product storage and preservation. The Nidec-Embraco NEK6212Z1 is a 1/2 HP hermetic reciprocating compressor specified for medium- and high-temperature refrigeration applications. Its piston-driven compression mechanism raises refrigerant vapor pressure within the sealed refrigeration system. This process supports refrigerant circulation and the appliance's cooling operation.

RECIPROCATING COMPRESSION:
The hermetic reciprocating design uses a piston moving inside a cylinder to compress refrigerant vapor. As the piston moves, the available cylinder volume decreases, increasing vapor pressure before discharge into the refrigeration circuit. The motor and compression mechanism operate within the sealed compressor assembly.

ELECTRICAL AND MOTOR CHARACTERISTICS:
The NEK6212Z1 has a specified electrical configuration of 115V, single-phase operation and a motor rating of 1/2 HP. Voltage and phase identify the required electrical supply, while horsepower indicates the motor's rated power class. These characteristics should be checked against the original equipment requirements when selecting a replacement.

REFRIGERATION APPLICATION AND R134a:
This compressor is specified for medium- and high-temperature refrigeration applications using R134a refrigerant. The refrigerant must correspond with the refrigeration system's design and operating requirements. Confirm the original equipment's refrigerant specification before selecting or installing a replacement compressor.

REPLACEMENT GUIDELINES:
Replacement may be appropriate when a confirmed compressor fault prevents the refrigeration appliance from maintaining the required temperature. It may also be necessary when the existing compressor is identified for replacement through the applicable equipment service information. Before ordering, compare the existing compressor's part number and applicable refrigeration-system requirements with the replacement requirements.

COMMON FAILURE SYMPTOMS:

  • The compressor does not start during an operating cycle.
  • Refrigeration appliances provide insufficient cooling.
  • The compressor repeatedly starts and stops.
  • Abnormal operating noise or vibration occurs.
  • Compressor shuts down during operation.

EQUIPMENT COMPATIBILITY:
The OEM Nidec-Embraco NEK6212Z1 Hermetic Reciprocating Compressor should be matched with a refrigeration appliance corresponding to its compressor configuration, 115V single-phase operation, R134a requirement, and applicable temperature range. Before installation, verify the original part number and compare the compressor characteristics with the applicable refrigeration-system requirements and original equipment documentation.

TECHNICAL SPECIFICATIONS:
Part Identification:
Brand: Nidec-Embraco
Part Number: NEK6212Z1
Product Type: Hermetic Reciprocating Refrigeration Compressor
Application: Medium and High-Temperature Refrigeration
Electrical Specifications:
Voltage: 115V
Phase: 1-Phase
Mechanical Specifications:
Horsepower: 1/2HP
Refrigeration Specifications:
Refrigerant: R134a

Write Your Own Review
You're reviewing:Nidec-Embraco NEK6212Z1 1/2HP Hermetic Reciprocating Compressor R134a 115V 1-Phase
Your Rating
Customer Questions
What maintenance is required for the Nidec-Embraco NEK6212Z1 Compressor?

Inspect refrigerant charge regularly and ensure proper levels to maintain efficient cooling. Keep electrical terminals tight and clean to prevent faults. Clean condenser coils and ensure adequate airflow to avoid overheating.

What are common issues with the Nidec-Embraco NEK6212Z1 Compressor?

  • Failure to start due to faulty start relay or capacitor.
  • Overheating from restricted airflow or dirty condenser.
  • Low cooling performance from refrigerant leaks or inefficiency.
  • Unusual noise from internal wear or loose mounting.

Can another 1/2HP compressor replace the Nidec-Embraco NEK6212Z1?

Not automatically. The replacement must also meet the required refrigerant, electrical, application, and compressor specifications.

Can an R290 compressor be used instead of the NEK6212Z1?

Not as a direct replacement. R290 and R134a systems have different refrigerant and safety requirements. Any conversion requires manufacturer approval and appropriate system modifications.

What happens if an R134a compressor is installed in equipment designed for a different refrigerant?

The compressor and refrigeration system may not operate as intended. Always use a compressor and refrigerant combination approved for the original equipment.

Why might a refrigeration appliance continue to have cooling problems after compressor replacement?

Other components, refrigerant-circuit issues, electrical faults, or control problems may be responsible. The complete refrigeration system should be inspected.

What should I check if the replacement compressor trips the electrical protection after installation?

Have a qualified technician inspect the electrical supply, wiring, starting components, and compressor installation to identify the cause before further operation.

Installation Steps

Step 1: Disconnect electrical power and recover refrigerant safely before removal.

Step 2: Remove old compressor, noting suction/discharge line positions and wiring connections.

Step 3: Install new compressor on mounting base, ensuring level placement and secure fastening.

Step 4: Braze suction and discharge lines using proper nitrogen purge to avoid contamination.

Step 5: Reconnect electrical terminals and check correct voltage.

Step 6: Evacuate system to deep vacuum, and check for leaks.

Step 7: Start unit and monitor pressure, sound, and temperature for stable operation.