Facebook Pixel

Nidec-Embraco NEK2168GK1 3/4HP Compressor R404A 115V 1-Phase

Special Price $514.56 Regular Price $571.17
Out of stock
SKU
NEK2168GK1
Nidec-Embraco NEK2168GK1 is a compressor used for the refrigeration of various applications to provide efficient cooling. It effectively cools the enclosed space and delivers an appropriate temperature for preserving by compressing R404A refrigerant. Often used in commercial freezers, ice makers, and other industrial refrigeration equipment requirements for steady and dependable cooling are met by this compressor. This compressor is critical in maintaining the right storage conditions in food processing plants, and pharmacies. 115V single phase and 3/4 HP is enough for it to perform functions that it needs for refrigeration purposes.
https://www.partshnc.com/media/catalog/product/n/e/nek2168gk1.jpg

Specifications

  • Type: Compressor
  • Power: 3/4 HP
  • Voltage: 115V
  • Application: Refrigeration
  • Weight: 27.98lbs
  • Temperature: -20°F-100°F
  • Phase: 1-Phase

Refrigeration equipment depends on controlled refrigerant circulation to maintain the cooling process. The Nidec-Embraco NEK2168GK1 compressor performs the compression stage within this cycle, preparing refrigerant vapor for continued movement through the refrigeration circuit. It is intended for refrigeration applications where the specified compressor configuration is required.

REFRIGERATION CYCLE AND COMPRESSION:
Compression is a key stage in the refrigeration cycle, as it raises the pressure of refrigerant vapor before the refrigerant enters the condenser. After releasing heat, the refrigerant continues through the remaining stages of the circuit before returning to the compressor. This pressure-driven process supports continuous refrigerant circulation and the system's overall cooling operation.

ELECTRICAL AND POWER REQUIREMENTS:
The 115V, single-phase electrical configuration identifies the listed power supply requirement for this compressor. Its 3/4 HP rating indicates the stated motor power classification. These characteristics are important when evaluating a replacement for existing refrigeration equipment because electrical supply and compressor power requirements must correspond with the equipment specifications.

REPLACEMENT GUIDELINES:
Replacement may be necessary when a compressor develops a fault that prevents normal operation or cannot maintain the required refrigeration performance. Before replacing the existing unit, establish whether the problem originates in the compressor or another part of the refrigeration system. Compare the NEK2168GK1 part number with the equipment manufacturer's parts documentation and confirm the approved replacement requirements before ordering.

COMMON FAILURE SYMPTOMS:

  • Compressor fails to start
  • Intermittent compressor operation
  • Unusual operating noise
  • Excessive vibration
  • Compressor stops during operation
  • Inconsistent refrigeration performance

EQUIPMENT COMPATIBILITY:
The Nidec-Embraco NEK2168GK1 is identified for refrigeration applications using the listed R404A refrigerant and 115V, single-phase electrical configuration. Specific compatible equipment models have not been established here. Before ordering, compare the existing compressor part number, equipment model, refrigerant requirement, electrical supply, and applicable compressor specifications with the manufacturer's documentation.

TECHNICAL SPECIFICATIONS:
Part Identification:
Brand: Nidec-Embraco
Part Number: NEK2168GK1
Product Type: Compressor
Application: Refrigeration
Mechanical Specifications:
Power: 3/4HP
Electrical Specifications:
Voltage: 115V
Phase: 1-Phase
Refrigerant Specifications:
Refrigerant: R404A

Write Your Own Review
You're reviewing:Nidec-Embraco NEK2168GK1 3/4HP Compressor R404A 115V 1-Phase
Your Rating
Customer Questions
What maintenance is required for the Nidec-Embraco NEK2168GK1 Compressor?

Regularly inspect the compressor for oil leaks, loose connections, and unusual noise. Clean surrounding areas to ensure proper ventilation and prevent overheating. Check refrigerant levels and electrical connections. Routine maintenance ensures efficiency, prolongs longevity, and prevents system failures.

What are common issues with the Nidec-Embraco NEK2168GK1 Compressor?

  • Failure to start or run consistently.
  • Overheating during operation.
  • Unusual humming, vibration, or noise.
  • Loose or corroded electrical connections affecting performance.

How can I find an approved replacement for the Nidec-Embraco NEK2168GK1?

Use the NEK2168GK1 part number to check the refrigeration equipment manufacturer's parts documentation. If the original compressor is unavailable, confirm an approved substitute through the equipment manufacturer or an authorized parts supplier.

Can I replace the NEK2168GK1 with a compressor that has a different voltage rating?

Only if the alternative is approved for the specific refrigeration equipment. The electrical supply requirements, motor specifications, and equipment design must be checked before selecting a compressor with a different voltage rating.

Is the NEK2168GK1 suitable for a refrigeration system designed for R404A?

The NEK2168GK1 is listed with R404A refrigerant. Confirm that the refrigeration equipment and replacement compressor documentation specify the same refrigerant and approved application before installation.

What could cause the NEK2168GK1 compressor to repeatedly trip electrical protection?

Possible causes include electrical supply irregularities, wiring problems, starting-component faults, or compressor-related issues. A qualified refrigeration technician should inspect the electrical circuit and compressor to identify the cause.

What information is needed to confirm NEK2168GK1 compressor compatibility with existing equipment?

Check the refrigeration unit's complete model and serial numbers, the original compressor part number, refrigerant requirement, electrical configuration, and manufacturer's replacement documentation. These details help establish whether the NEK2168GK1 is an appropriate replacement.

Installation Steps

Step1: Turn off power to the refrigeration unit at the breaker and unplug it.

Step2: Recover refrigerant per regulations before opening the system.

Step3: Disconnect electrical leads and refrigerant lines from the old compressor.

Step4: Remove the old compressor and clean the mounting area.

Step5: Install the new compressor, reconnect lines with proper brazing, and tighten fittings.

Step6: Evacuate, recharge with R404A, restore power, and test for correct operation and leaks.