Product Description
If you need to replace an aging system across a large residential space, matching the equipment to the home's capacity and ductwork layout is essential. The MRCOOL Hyper Heat 2nd Gen Central Ducted Heat Pump CENTRAL-48-HP-230B00-O is a 48K BTU, 4-ton heat pump split system designed for spaces from 1,501 to 2,000 square feet.
The system provides 48,000 BTU of cooling capacity and 50,000 BTU of heating capacity. Its efficiency ratings include up to 16.5 SEER2, 10.5 EER2, and 9.5 HSPF2-4, along with an 8.0 HSPF2-5 rating. Advanced inverter technology adjusts system operation according to changing heating and cooling demand, supporting the system's year-round heating and cooling design.
The MRCOOL Hyper Heat 48K BTU heat pump uses R-454B refrigerant as part of its current system configuration. The combination of inverter technology and R-454B refrigerant is part of the specified Hyper Heat 2nd Gen system design.
Installation flexibility is supported through multiple mounting configurations. The system operates on 208–230V power and supports vertical installation in either downflow or upflow configuration, as well as horizontal installation with right- or left-side orientation. It is compatible with the MRCOOL VersaPro™ Central Ducted Air Handler, making it suitable for a new installation or replacement of an outdated system.
Customer Feedback: “Managing inconsistent temperatures across the home was a constant concern, but the system’s inverter technology has helped provide more consistent heating and cooling without requiring frequent adjustments.”
The inverter-driven operation adjusts compressor speed according to heating or cooling demand, allowing the system to respond as indoor comfort requirements change.
For larger residential spaces within the specified coverage range, the MRCOOL CENTRAL-48-HP-230B00-O combines high-capacity heating and cooling with inverter operation and flexible installation configurations.
Product Highlights
| Feature | Benefits |
|---|---|
| Advanced Inverter Technology | Supports the system's heating and cooling operation while adjusting system output according to operating demand. |
| Vertical Installation | Supports both downflow and upflow mounting configurations for different installation arrangements. |
| Horizontal Installation | Supports right- or left-side horizontal configurations for additional installation flexibility. |
| VersaPro™ Compatibility | Works with the MRCOOL VersaPro™ Central Ducted Air Handler for the specified system configuration. |
MRCOOL Hyper Heat 2nd Gen 48K BTU Central Ducted Heat Pump 16.5 SEER2 R-454B CENTRAL-48-HP-230B00-O Specs
| Category | Specification | Details |
|---|---|---|
| General | Mount Type | Vertical (Downflow or Upflow), Horizontal (Right or Left) |
| 20kW - | MVPHK20 | |
| Performance | Cooling Capacity | 48,000 BTU |
| Heating Capacity | 50,000 BTU | |
| Noise Level (Hi/Mi/Lo) | 65 db(A) | |
| Coverage Area | 1,501-2,000 square feet | |
| Noise Level (Turbo/Hi/Mi/Lo/Si) | N/A / 52 / 50 / 34 / N/A dB(A) | |
| Airflow (TURBO/Hi/Mi/Lo) | 1601 / 1471 / 1283 / 1094 / N\A CFM | |
| Efficiency | SEER2 | 16.5 |
| EER2 | 10.5 | |
| HSPF2-4 | 9.5 | |
| HSPF2-5 (Condenser) | 8 | |
| HSPF2-5 (Air Handler) | 8.0 | |
| Refrigeration | Outdoor Operating Temperature Range | -22 °F - 120°F |
| Refrigerant | R454B / 134.04 oz | |
| Liquid Line Size | 3/8" | |
| Suction Line Size | 3/4" | |
| Electrical | Electrical Requirements (Condenser) | Requires a minimum of 208-230V/60Hz/38-40A (please check your home meets this electrical requirement prior to purchase) |
| Electrical Requirements (Air Handler) | Requires a minimum of 208-230V/60Hz/14.5/11.0-15A (please check your home meets this electrical requirement prior to purchase) | |
| Compatible Heat Kits | 8kW - MVPHK08, 10kW - MVPHK10, 15kW - MVPHK15 | |
| Warranty | Warranty (Condenser) | 10 Years Compressor, 10 Years Parts |
| Warranty (Air Handler) | 10 Years Parts | |
| Dimensions & Weight | Dimensions (Condenser) | 38.58" W x 16.34" D x 38.39" H |
| Dimensions (Air Handler) | 24.49" W x 21.02" D x 52.99" H | |
| Weight (Condenser) | 201.06 lbs | |
| Weight (Air Handler) | 162.92 lbs |