The KMC Controls MCP-1130-5520 Pneumatic Damper Actuator is a 3" post mounted actuator for precise airflow control in HVAC systems. It operates within an 8-13 PSI pressure range and adjusts dampers in air handling units, ventilation systems and Variable Air Volume applications to minimize airflow. The actuator produced by this ensures smooth operation, intakes less energy and maintains a more constant indoor air quality. The construction of this system reduced the maintenance needs and extends the equipment durability. Benefits are efficient conditions, lower operation costs and dependable performance make it a necessity for commercial and industrial HVAC systems.
Manufacturer:
https://www.partshnc.com/media/catalog/product/m/c/mcp-1130-5520_1.jpg

Specifications

  • Type: Pneumatic Damper Actuator
  • Size: 3"
  • Pressure: 8-13 PSI
  • Mount Type: Post-Mount
Manufacturer Name: KMC Controls
Product Number: MCP-1130-5520
OEM Part Number: MCP-1130-5520
Product Description: 3"Pnuem Damp Act,8-13#,Post Mt
Weight:3.68lbs/1669.22g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:KMC Controls MCP-1130-5520 3" Pneumatic Damper Actuator 8-13 PSI Post Mount
Your Rating
Customer Questions
What maintenance is required for the KMC Controls MCP-1130-5520 Pneumatic Damper Actuator?

Inspect air supply lines and fittings regularly to ensure stable operation. Check for leaks and tighten post mount hardware to prevent vibration. Clean external surfaces and verify actuator stroke movement for smooth damper control.

What are common issues with the KMC Controls MCP-1130-5520 Pneumatic Damper Actuator?

  • Air leakage from fittings or diaphragm failure.
  • Inconsistent actuator response due to pressure fluctuation.
  • Binding or sticking caused by misalignment of post mount.
  • Reduced stroke performance from worn internal seals.
  • Slow operation due to restricted airflow.

Installation Steps

Step 1: Isolate air supply and verify HVAC damper is secure.

Step 2: Mount actuator on post bracket aligned with damper shaft.

Step 3: Connect pneumatic tubing to port per diagram.

Step 4: Adjust linkage for full open/close movement.

Step 5: Test pressure response gradually, check smooth motion.

Step 6: Secure fittings, restore air supply, verify safe operation.