Facebook Pixel

Siemens Combustion LMV37.420A1 Burner Control Unit 50-60Hz 110V

Special Price $1,264.16 Regular Price $1,403.21
In stock
SKU
LMV37.420A1

The Siemens Combustion LMV37.420A1 Control Unit is a microprocessor-based regulator for mid to high-power forced-draft burners in HVAC equipment. It draws power at 50–60 Hz and 110 V. By carefully regulating the fuel and air mixture, this unit precisely regulates the combustion process, assuring highest efficiency, fewer emissions, and secure operation. It features an adjustable speed drive air fan, a computerised air-fuel ratio control, a built-in valve proving structure, and capacity for up to two burners. Typical uses for the LMV37.420A1 include industrial heaters, furnaces, and boilers. It offers perks like lower fuel costs, fewer of an impact on the environment, and extended equipment life by optimising combustion.

https://www.partshnc.com/media/catalog/product/l/m/lmv37-420a1.jpg
Manufacturer Name: Siemens Combustion
Product Number: LMV37.420A1
OEM Part Number: LMV37.420A1
Product Description: Control Unit 110V 50-60Hz
Weight:1.86lbs/843.68g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Siemens Combustion LMV37.420A1 Burner Control Unit 50-60Hz 110V
Your Rating
Customer Questions
What maintenance is required for the Siemens LMV37.420A1 Burner Control Unit?

Regularly inspect the unit for dust, corrosion, or loose wiring. Ensure all electrical connections are tight and clean gently with a dry cloth if needed. Always disconnect power before handling to ensure safety and accirate burner operation.

What are common issues with the Siemens LMV37.420A1 Burner Control Unit?

  • Failure to ignite the burner.
  • Erratic or intermittent flame detection.
  • Faulty electrical connections.
  • Unexpected system shutdowns.

Installation Steps

Step1: Turn off power to the burner and disconnect the unit from the electrical supply.

Step2: Remove the burner access panel to locate the existing control unit.

Step3: Carefully disconnect all wires, noting their original positions.

Step4: Unscrew and remove the old burner control unit.

Step5: Install the new unit in the same location and reconnect all wiring correctly.

Step6: Replace the access panel, restore power, and test the burner for proper ignition and operation.